Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
5 -  36 
5. OPERATION 
 
5.6.3 Count type home position return 
In count type home position return, a motion is made over the distance set in parameter No.PC08 (moving 
distance after proximity dog) after detection of the proximity dog front end. The position where the first Z-phase 
signal is given after that is defined as a home position. Hence, if the proximity dog (DOG) is 10ms or longer, 
there is no restriction on the dog length. This home position return method is used when the required proximity 
dog length cannot be reserved to use dog type home position return or when the proximity dog (DOG) is 
entered electrically from a controller or the like. 
 
(1) Devices, parameters 
Set the input devices and parameters as follows. 
 
Item Device/Parameter 
used  Description 
Automatic/manual selection (RYn6) 
Turn RYn6 ON. 
Manual home position return mode 
selection 
Point table No. selection 1 to 8  
(RYnA to RYnE, RY(n 2)3 to RY(n 2)5) 
RYnA to RYnE, RY(n 2)3 to RY(n 2)5 are 
turned off. 
Remote register-based 
position/speed setting 
(Only when two stations are  
 occupied) 
Position/speed specifying system selection 
(RY(n 2)A) 
Turn RY(n 2)A ON. 
Count type home position return 
Parameter No.PC02 
1 : Count type home position return is 
selected. 
Home position return direction 
Parameter No.PC03 
Refer to section 5.6.1 (2) and choose home 
position return direction. 
Dog input polarity 
Parameter No.PD16 
Refer to section 5.6.1 (2) and choose dog 
input polarity. 
Home position return speed 
Parameter No.PC04 
Set speed until detection of dog. 
Creep speed 
Parameter No.PC05 
Set speed after detection of dog. 
Home position shift distance 
Parameter No.PC06 
Set when shifting the home position, starting 
at the first Z-phase signal given after passage 
of the proximity dog front end and movement 
over the moving distance. 
Moving distance after proximity dog  Parameter No.PC08 
Set the moving distance after passage of 
proximity dog front end. 
Home position return 
acceleration/deceleration time 
constants 
Point table No.1 
Use the acceleration/deceleration time 
constants of point table No.1. 
Home position return position data  Parameter No.PC07 
Set the current position at home position 
return completion.