Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
8 -  10 
8. PARAMETER UNIT (MR-PRU03) 
 
 (2) Monitor display list 
The following table lists the items and descriptions of monitor display. 
 
Status display 
Display on 
parameter 
unit 
Unit Description Display 
range 
 
Current position 
Cur posit 
10
STM
 
mm 
The current position from the machine home position of 0 is 
displayed. 
9999999 to 
9999999 
Command position 
Cmd Posit 
10
STM
 
mm 
The command position is displayed. 
9999999 to 
9999999 
Command remaining 
distance 
Cmd remin 
10
STM
 
mm 
The command remaining distance of the currently selected 
point table is displayed. 
999999999 to 
999999999 
Point table No. 
Pnttbl No 
 
The point table No. being executed is displayed. 
0 to 255 
Cumulative feedback 
pulses 
Pulse F/B 
pulse 
Feedback pulses from the servo motor encoder are counted 
and displayed. 
When the value exceeds  999999, characters are displayed 
smaller. 
Press the "RESET" key of the parameter unit to reset the 
display value to zero. 
999999999 to 
999999999 
Servo motor speed 
Speed F/B 
r/min 
The servo motor speed is displayed. 
"-" is added to the speed of the servo motor rotating in the 
reverse rotation. 
The value rounded off is displayed in  0.1r/min. 
7200 to 7200 
Droop pulse 
Droop Pls 
pulse 
The number of droop pulses in the deviation counter is 
displayed. 
"- " is added to the reverse pulses. 
When the value exceeds ±999999, characters are displayed 
smaller. 
The number of pulses displayed is in the encoder pulse unit. 
999999999 to 
999999999 
Regenerative load 
ratio 
Regn Load 
 
The ratio of regenerative power to permissible regenerative 
power is displayed in %. 
When regenerative option is used, the ratio to the permissible 
regenerative power is displayed. 
0 to 100 
Effective load ratio 
Effc Load 
 
The continuous effective load current is displayed. 
The effective value is displayed relative to the rated current of 
100%. 
0 to 300 
Peak load ratio 
Peak Load 
 
The maximum torque is displayed. 
The highest value in the past 15 seconds is displayed relative 
to the rated torque of 100%. 
0 to 400 
Instantaneous 
torque 
Instn Trq 
 
Torque that occurred instantaneously is displayed. 
The value of the torque that occurred is displayed in real time 
relative to the rate torque of 100%. 
0 to 400 
Within one-revolution 
position 
Cyc posit 
pulse 
Position within one revolution is displayed in encoder pulses. 
The value returns to 0 when it exceeds the maximum number 
of pulses. 
The value is incremented in the CCW direction of rotation. 
0 to 262143 
ABS counter 
Abs count 
rev 
Travel value from the home position in the absolute position 
detection systems is displayed in terms of the absolute 
position detectors counter value. 
32768 to 32767 
Load inertia moment 
ratio 
Moment Rt 
Multiplier 
( 1) 
The estimated ratio of the load inertia moment to the servo 
motor shaft inertia moment is displayed. 
0.0 to 300.0 
Bus voltage 
P-N Volt 
The voltage (across P-N or P  - N ) of the main circuit 
converter is displayed. 
0 to 900