Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
9 -  8 
9. GENERAL GAIN ADJUSTMENT 
 
(c) Adjustment description  
1) Speed loop gain (parameter No.PB09) 
This parameter determines the response level of the speed control loop. Increasing this value 
enhances response but a too high value will make the mechanical system liable to vibrate. The 
actual response frequency of the speed loop is as indicated in the following expression. 
 
Speed loop response 
frequency(Hz)
 (1   ratio of load inertia moment to servo motor inertia moment) 2
Speed loop gain setting
 
2) Speed integral compensation (VIC: parameter No.PB10) 
To eliminate stationary deviation against a command, the speed control loop is under proportional 
integral control. For the speed integral compensation, set the time constant of this integral control. 
Increasing the setting lowers the response level. However, if the load inertia moment ratio is large or 
the mechanical system has any vibratory element, the mechanical system is liable to vibrate unless 
the setting is increased to some degree. The guideline is as indicated in the following expression. 
 
Speed integral compensation
setting(ms)
Speed loop gain setting/ (1   ratio of load inertia moment to 
  servo motor inertia moment setting   0.1)
2000 to 3000
 
3) Model loop gain (PG1: Parameter No.PB07) 
This parameter determines the response level to a position command. Increasing the model loop 
gain improves track ability to a position command, but a too high value will make overshooting liable 
to occur at the time of setting. 
 
(1    ratio of load inertia moment to servo mortar inertia moment)
1
4
1
8
to
Speed loop gain setting
Model loop gain 
guideline