13 -  10 
13 CHARACTERISTICS 
 
13.4 Cable flexing life 
The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed 
values, provide a little allowance for these values. 
1   10
7
5   10
7
1   10
8
5   10
6
1   10
6
5   10
5
1   10
5
5   10
4
1   10
4
5   10
3
1   10
3
a
b
F
le
xi
ng
 li
fe
 [t
im
es
]
4
7
10
20
40
70 100
200
Flexing radius [mm]
b : Standard encoder cable 
     Standard motor power cable
     Standard motor brake cable
     
a : Long flex life encoder cable 
     Long flex life motor power cable
     Long flex life motor brake cable
 
13.5 Inrush currents at power-on of main circuit and control circuit 
The following table indicates the inrush currents (reference data) that will flow when the maximum permissible 
voltage (200V class: 253VAC, 400V class: 528VAC) is applied at the power supply capacity of 2500kVA and 
the wiring length of 1m. 
 
Inrush currents (A
0
-
p
Servo amplifier 
Main circuit power supply (L
1
, L
2
, L
3
Control circuit power supply (L
11
, L
21
MR-J3-10T1 to 40T1 
38A (Attenuated to approx. 14A in 10ms) 
MR-J3-10T to 60T 
30A (Attenuated to approx. 5A in 10ms) 
MR-J3-70T 100T 
54A (Attenuated to approx. 12A in 10ms) 
MR-J3-200T 350T 
120A (Attenuated to approx. 12A in 20ms) 
20 to 30A 
(Attenuated to approx. 0A in 1 to 2ms) 
MR-J3-500T 
44A (Attenuated to approx. 20A in 20ms) 
MR-J3-700T 
88A (Attenuated to approx. 20A in 20ms) 
MR-J3-11KT 
MR-J3-15KT 
MR-J3-22KT 
235A (Attenuated to approx. 20A in 20ms) 
30A (Attenuated to approx. 0A in 3ms) 
MR-J3-60T4 100T4 
100A (Attenuated to approx. 5A in 10ms) 
MR-J3-200T4 
120A (Attenuated to approx. 12A in 20ms) 
40 to 50A 
(Attenuated to approx. 0A in 2ms) 
MR-J3-350T4 500T4 
66A (Attenuated to approx. 10A in 20ms) 
MR-J3-700T4 
67A (Attenuated to approx. 34A in 20ms) 
41A (Attenuated to approx. 0A in 3ms) 
MR-J3-11KT4 
MR-J3-15KT4 
MR-J3-22KT4 
325A (Attenuated to approx. 20A in 20ms) 
45A (Attenuated to approx. 0A in 3ms) 
 
Since large inrush currents flow in the power supplies, always use no-fuse breakers and magnetic contactors. 
(Refer to section 14.10.) 
When circuit protectors are used, it is recommended to use the inertia delay type that will not be tripped by an 
inrush current.