Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
14 -  60 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.8 Heat sink outside mounting attachment (MR-J3ACN) 
Use the heat sink outside mounting attachment to mount the heat generation area of the servo amplifier in the 
outside of the control box to dissipate servo amplifier-generated heat to the outside of the box and reduce the 
amount of heat generated in the box, thereby allowing a compact control box to be designed. 
In the control box, machine a hole having the panel cut dimensions, fit the heat sink outside mounting 
attachment to the servo amplifier with the fitting screws (4 screws supplied), and install the servo amplifier to 
the control box. 
The environment outside the control box when using the heat sink outside mounting attachment should be 
within the range of the servo amplifier operating environment conditions. 
The heat sink outside mounting attachment of MR-J3ACN can be used for MR-J3-11KT(4) to MR-J3-22KT(4). 
 
(1) Panel cut dimensions 
 
236
255
270
Ap
p
ro
x.
125
33
1
39
.5
535
510
18
203
39.
5
4-M10 Screw
Punched
hole
[Unit : mm]
 
(2) How to assemble the attachment for a heat sink outside mounting attachment 
Screw
(2 places)
Attachment