15. COMMUNICATION FUNCTION 
 
15.5.13 Other commands 
(1) Servo motor side pulse unit absolute position 
Read the absolute position in the servo motor side pulse unit. 
Note that overflow will occur in the position of 8192 or more revolutions from the home position. 
 
(a) Transmission 
Send command [0][2] and data No. [9][0]. 
Command Data 
No. 
[0][2] [9][0] 
 
(b) Reply 
The slave station sends back the requested servo motor side pulses. 
Absolute value is sent back in hexadecimal in
the servo motor side pulse unit.
(Must be converted into decimal)
 
For example, data "000186A0" is 100000 [pulse] in the motor side pulse unit. 
 
(2) Command unit absolute position 
Read the absolute position in the command unit. 
 
(a) Transmission 
Send command [0][2] and data No. [9][1]. 
Command Data 
No. 
[0][2] [9][1] 
 
(b) Reply 
The slave station sends back the requested command pulses. 
Absolute value is sent back in hexadecimal in the
command unit.
(Must be converted into decimal)
 
For example, data "000186A0" is 100000 [pulse] in the command unit. 
 
(3) Software version 
Reads the software version of the servo amplifier. 
 
(a) Transmission 
Send command [0][2] and data No.[7][0]. 
Command Data 
No. 
[0][2] [7][0] 
 
(b) Reply 
The slave station returns the software version requested. 
Software version (15 digits)
Space