16. INDEXER POSITIONING OPERATION 
 
No.  Symbol 
Name and function 
Initial value 
Unit 
Setting range
PC46  *STN  Indexer positioning operation number of stations/rotation 
Set the number of stations (dividing number) per machine rotation. When 
the setting value is 2 or lower, the number of stations is set to 2. 
 
0000h Number 
of 
stations 
0000h 
to 
00FFh 
 
 
 
Setting value 
Number of 
stations 
 
 
 
 
  
 
0000 
2   
 
 
 
  
 
0001 
2   
 
 
 
  
 
0002 
2   
 
 
 
  
 
0003 
3   
 
 
 
  
 
0004 
4   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
00FF 
255   
 
 
 
 
 
 
 
 
 
PC47  PSST  Indexer positioning operation station home position shift distance 
This parameter is available only in the absolute position detection system. 
Set the distance for shifting the home position toward the set home 
position in number of pulses. 
This shift distance does not become valid immediately after the home 
position setting. It becomes valid after turning off and then on the power. 
When the sift distance is larger than the in-position range, the in position 
(RXn1) does not turn on at power-on. 
Set the number of pulses to be shifted after converting it into hexadecimal. 
The setting range is from  2000 to 2000 pulse. 
0000h pulse Refer 
to 
name and 
function 
column 
PC48 
For manufacturer setting 
0000h 
PC49 
Do not change this value by any means. 
0000h 
PC50 
 
 
0000h 
 
 
 
(3) Alarm history clear 
The alarm history can be confirmed by using the MR Configurator. The servo amplifier stores one current 
alarm and five past alarms from when its power is switched on first. To control alarms which will occur 
during operation, clear the alarm history using parameter No.PC18 (alarm history clear) before starting 
operation. Clearing the alarm history automatically returns to "
0". 
This parameter is made valid by switching power off, then on after setting. 
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
Parameter No.16