Mitsumi electronic mr-j3-b ユーザーズマニュアル

ページ / 270
3. SIGNALS AND WIRING 
3 -  36 
 
(a) Connection 
1)  For an SSCNET III cable in the shipping status, the tube for protecting the optical cord end is put 
on the end of connector. Remove this tube. 
 
2)  Remove the CN1A and CN1B connector caps of the servo amplifier. 
 
3)  While holding a tab of the SSCNET III cable connector, make sure to insert it into the CN1A and 
CN1B connectors of the servo amplifier until you hear the click. If the end face of the optical cord 
tip is dirty, optical transmission is interrupted and it may cause malfunctions. If it becomes dirty, 
wipe with a bonded textile, etc. Do not use solvent such as alcohol. 
Click
Tab
Servo amplifier
Servo amplifier
CN1A
CN1B
CN1A
CN1B
 
(b) Disconnection 
While holding a tab of the SSCNET III cable connector, pull out the connector. 
When pulling out the SSCNET III cable from the servo amplifier, be sure to put the cap on the 
connector parts of the servo amplifier to prevent them from becoming dirty. For the SSCNET III 
cable, attach the tube for protecting the optical cord's end face on the end of the connector.