&KHFNLQJ)RU2SHQ=RQHV
 
8VLQJWKH>∗@.H\
B
efore arming your system, all protected doors, windows and other protection zones 
must be closed or bypassed, otherwise the keypad will display a "Not Ready" message.  
 
Use the READY key to display all faulted zones, making it easier for you to identify 
and secure any open zone. 
 
1. Press [
∗] (do not enter code first) to display faulted 
zones. 
2.  Secure or bypass the zones displayed. 
3. 
The keypad’s READY indicator lights when all 
protection zones have been either closed or bypassed.  
4.  Arm the system as desired. 
Alpha Display: 
(-7%61)(  46)77 ∗
83 7,3; *%9087
 
Fixed-Word Display: 
Zone no. and “NOT READY”
 
 
Voice Status:
 Voice Keypads (if installed), can announce system status and faulted 
zones (up to 3 zone descriptors) if the Voice Status feature is turned on. 
 
To turn the Voice Status feature on/off: 
 #   +   0    +   2   +   4     
(also turns on Voice Chime mode; see Chime mode section) 
 
To announce Status:  Press [#] FUNCTION + [0] VOICE + [
∗] STATUS key. 
 
(Announces current system status; e.g., “Disarmed Ready to 
Arm.”) 
 
To announce faults:   Press [#] FUNCTION + [0] VOICE + [
∗] STATUS + [∗] again 
within 5 seconds of the first press. (Announces up to three 
faulted zones with their zone descriptors, if programmed.)