JAI TS-1327EN ユーザーズマニュアル

ページ / 112
 
 
 
 
 
Appendix B: J-Panel Functional & Connector Description 
81 
VIS-CAM System 
6.11.4  Connector physical Interface 
Table 33 
Connector table 
Pin Signal  Description 
Connection to 
1 Trig0+ 
Positive trigger input to camera 0 
 
Trig0- 
Negative trigger input to camera 0 
 
3 Trig1+ 
Positive trigger input to camera 1 
 
Trig1- 
Negative trigger input to camera 1 
 
 
6.12  X15: Lane Controller interface 
6.12.1  Functionality 
The signal path for the Lane Controller is shown in Figure 83. The signal lines symbolizes the two 
balanced RS485 wires. 
6.12.1 (a) Common Lane Controller 
If one lane controller is to be connected to camera 0 and camera 1, LC DATA terminals labelled D0 
on X15 is used. 
The signal runs to Camera 0 and is daisy chained back. When S2 is in position “OPEN” D0 is 
connected to Camera 1 and daisy chained back to connector X4. X4 has connection to a termination 
resistor that is activated when no plug is inserted into X4. If more J-Panels are to be connected to 
the same lane controller, see Figure 6.12.5. 
6.12.1 (b) Two Lane Controllers 
If separate lane controllers are to be connected to the two cameras, databus D0 is connected to 
Camera #0 and databus D1 is connected to Camera #1. Switch S2 must then be in position “TERM”. 
The 120 ? termination resistor is then connected between the RS485 wires. 
Figure 83.  Lane controller setup diagram. 
 
6.12.2  Connector specification 
Connector type:  
5 pole WAGO pluggable terminal block 
Connector on board:  
WAGO 734-235 
Cable part:  
WAGO 734-205 
6.12.3  Connector signal specifications 
D0 and D1 are RS485 data bus signals from the Lane Controller.