IBM 8688 ユーザーズマニュアル

ページ / 262
SCSI
 
connector:
 
This
 
connector
 
is
 
used
 
to
 
attach
 
external
 
SCSI
 
devices
 
to
 
the
 
server.
 
Server
 
power
 
features
 
When
 
the
 
server
 
is
 
connected
 
to
 
an
 
ac
 
power
 
source
 
but
 
is
 
not
 
turned
 
on,
 
the
 
operating
 
system
 
does
 
not
 
run,
 
and
 
all
 
core
 
logic
 
except
 
for
 
the
 
service
 
processor
 
is
 
shut
 
down;
 
however,
 
the
 
server
 
can
 
respond
 
to
 
requests
 
from
 
the
 
service
 
processor,
 
such
 
as
 
a
 
remote
 
request
 
to
 
turn
 
on
 
the
 
server.
 
The
 
power-on
 
LED
 
flashes
 
to
 
indicate
 
that
 
the
 
server
 
is
 
connected
 
to
 
ac
 
power
 
but
 
is
 
not
 
turned
 
on.
 
Turning
 
on
 
the
 
server
 
Approximately
 
20
 
seconds
 
after
 
the
 
server
 
is
 
connected
 
to
 
ac
 
power,
 
the
 
power-control
 
button
 
becomes
 
active,
 
and
 
you
 
can
 
turn
 
on
 
the
 
server
 
and
 
start
 
the
 
operating
 
system
 
by
 
pressing
 
the
 
power-control
 
button.
 
The
 
server
 
can
 
also
 
be
 
turned
 
on
 
in
 
any
 
of
 
the
 
following
 
ways:
 
v
   
If
 
a
 
power
 
failure
 
occurs
 
while
 
the
 
server
 
is
 
turned
 
on,
 
the
 
server
 
will
 
restart
 
automatically
 
when
 
power
 
is
 
restored.
 
v
   
If
 
ac
 
power
 
is
 
present,
 
the
 
server
 
can
 
be
 
turned
 
on
 
from
 
the
 
Remote
 
Supervisor
 
Adapter
 
user
 
interface.
 
v
   
The
 
Wake
 
on
 
LAN
 
feature
 
can
 
turn
 
on
 
the
 
server.
Notes:
  
1.
   
The
 
power
 
supplies
 
are
 
hot-swappable
 
and
 
redundant
 
only
 
at
 
200-240
 
V
 
ac.
 
2.
   
Both
 
power
 
supplies
 
must
 
be
 
connected
 
to
 
the
 
power
 
source
 
for
 
operation
 
at
 
100-127
 
V
 
ac.
 
3.
   
During
 
normal
 
operation,
 
both
 
power
 
supplies
 
must
 
be
 
installed
 
for
 
proper
 
operation.
 
4.
   
While
 
the
 
server
 
is
 
powering
 
up,
 
the
 
power-on
 
LED
 
on
 
the
 
front
 
of
 
the
 
server
 
is
 
lit.
 
When
 
the
 
server
 
is
 
connected
 
to
 
ac
 
power
 
but
 
is
 
not
 
turned
 
on,
 
the
 
power-on
 
LED
 
on
 
the
 
front
 
of
 
the
 
server
 
flashes.
Turning
 
off
 
the
 
server
 
When
 
you
 
turn
 
off
 
the
 
server
 
and
 
leave
 
it
 
connected
 
to
 
ac
 
power,
 
the
 
server
 
can
 
respond
 
to
 
requests
 
from
 
the
 
service
 
processor,
 
such
 
as
 
a
 
remote
 
request
 
to
 
turn
 
on
 
the
 
server.
 
To
 
remove
 
all
 
power
 
from
 
the
 
server,
 
you
 
must
 
disconnect
 
it
 
from
 
the
 
power
 
source.
 
Some
 
operating
 
systems
 
require
 
an
 
orderly
 
shutdown
 
before
 
you
 
turn
 
off
 
the
 
server.
 
See
 
your
 
operating-system
 
documentation
 
for
 
information
 
about
 
shutting
 
down
 
the
 
operating
 
system.
   
8
 
IBM
 
xSeries
 
450
 
Type
 
8688:
 
Hardware
 
Maintenance
 
Manual
 
and
 
Troubleshooting
 
Guide