IBM 8688 ユーザーズマニュアル

ページ / 262
6.
   
Locate
 
the
 
CMOS
 
recovery
 
jumper
 
(J19)
 
on
 
the
 
I/O
 
board.
 
The
 
following
 
illustration
 
shows
 
the
 
location
 
of
 
the
 
jumper
 
on
 
the
 
I/O
 
board.
 
1
2
3
CMOS recovery
jumper (J19)
     
7.
   
Move
 
the
 
CMOS
 
recovery
 
jumper
 
from
 
pins
 
1
 
and
 
2
 
to
 
pins
 
2
 
and
 
3.
  
8.
   
Wait
 
60
 
seconds;
 
then,
 
return
 
the
 
CMOS
 
recovery
 
jumper
 
to
 
pins
 
1
 
and
 
2.
  
9.
   
Replace
 
fans
 
3
 
and
 
4.
 
10.
   
Close
 
the
 
cover
 
(see
 
 
 
 
 
 
 
11.
   
Connect
 
the
 
server
 
to
 
a
 
power
 
source,
 
keyboard,
 
monitor,
 
and
 
mouse.
 
12.
   
Turn
 
on
 
the
 
server.
 
The
 
EFI
 
Boot
 
Manager
 
program
 
starts.
 
13.
   
Follow
 
the
 
instructions
 
to
 
erase
 
the
 
existing
 
password
 
or
 
create
 
a
 
new
 
password.
 
14.
   
Select
 
Save
 
Settings,
 
and
 
press
 
Enter.
Power
 
checkout
 
Power
 
problems
 
can
 
be
 
difficult
 
to
 
solve.
 
For
 
example,
 
a
 
short
 
circuit
 
can
 
exist
 
anywhere
 
on
 
any
 
of
 
the
 
power
 
distribution
 
buses.
 
Usually
 
a
 
short
 
circuit
 
will
 
cause
 
the
 
power
 
subsystem
 
to
 
shut
 
down
 
because
 
of
 
an
 
overcurrent
 
condition.
 
Follow
 
this
 
general
 
procedure
 
for
 
troubleshooting
 
power
 
problems:
 
1.
   
Turn
 
off
 
the
 
server,
 
and
 
disconnect
 
all
 
ac
 
power
 
cords.
 
2.
   
Check
 
for
 
loose
 
cables
 
in
 
the
 
power
 
subsystem.
 
Also
 
check
 
for
 
short
 
circuits;
 
for
 
example,
 
a
 
loose
 
screw
 
might
 
be
 
causing
 
a
 
short
 
circuit
 
on
 
a
 
circuit
 
board.
 
3.
   
Remove
 
adapters
 
and
 
disconnect
 
the
 
cables
 
and
 
power
 
connectors
 
to
 
all
 
internal
 
and
 
external
 
devices
 
until
 
the
 
server
 
is
 
at
 
the
 
minimum
 
configuration
 
required
 
to
 
start
 
the
 
server
 
(see
 
the
 
note
 
about
 
minimum
 
operating
 
requirements
 
on
 
page
 
 
4.
   
Reconnect
 
all
 
ac
 
power
 
cords,
 
and
 
turn
 
on
 
the
 
server.
 
If
 
the
 
server
 
starts
 
successfully,
 
replace
 
adapters
 
and
 
devices
 
one
 
at
 
a
 
time
 
until
 
the
 
problem
 
is
 
isolated.
 
If
 
the
 
server
 
does
 
not
 
start
 
up
 
from
 
the
 
minimal
 
configuration,
 
replace
 
FRUs
 
of
 
the
 
minimal
 
configuration
 
one
 
at
 
a
 
time
 
until
 
the
 
problem
 
is
 
isolated.
 
To
 
use
 
this
 
method,
 
it
 
is
 
important
 
to
 
know
 
the
 
minimum
 
configuration
 
required
 
for
 
a
 
system
 
to
 
start
 
(see
 
the
 
minimum
 
configuration
 
requirements
 
at
 
 
 
 
 
   
74
 
IBM
 
xSeries
 
450
 
Type
 
8688:
 
Hardware
 
Maintenance
 
Manual
 
and
 
Troubleshooting
 
Guide