June 1999
Maintenance Object Repair Procedures
9-458
DAT-LINE (Data Line Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors.
b. Indicates the circuit pack has been removed or has been insane for more
than 11-minutes. To clear the error, reseat or replace the circuit pack.
c. Error type 769 indicates that the data line circuit pack found an error in the
transmit/receive circuitry of an administered data line when the circuit
pack was inserted. Perform the following:
pack was inserted. Perform the following:
1. Enter busyout board UUCSS for the circuit pack on which the port
resides.
2. Enter reset board UUCSS. Check the Error Log to determine if
Error Type 769 is logged again for DAT-LINE. Make sure that the
Active Alarms Only
field is set to
n
.
If error type 769 reappears, replace the data line circuit pack. If
Error Type 769 does not reappear, proceed to Step 3.
Error Type 769 does not reappear, proceed to Step 3.
3. Enter release board UUCSS.
Table 9-190.
Data Line Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1
Digital Looparound
Test (#171)
Test (#171)
MINOR
ON
test port UUCSSpp s r 2
15(a)
Any
Audit Update Test
(#36)
(#36)
18
0
Busyout port
UUCSSpp
UUCSSpp
WARNING
OFF
rel port UUCSSpp
130 (b)
None
WARNING
ON
test port UUCSSpp sh
257
Conference Circuit
Test (#7)
Test (#7)
MINOR
ON
test port UUCSSpp l r 2
513
NPE Crosstalk Test
(#6)
(#6)
MINOR
ON
test port UUCSSpp l r 2
769(c)
40983
None