DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Additional Maintenance Procedures 
6-35
Analog Tie Trunk Back-to-Back Testing 
6
10. Locate the Tie Trunk port terminal connections at the cross-connect field. 
Consult the appropriate table below for either 110-type or 66-type 
hardware.
11. At the cross-connect field, disconnect outside trunk facilities from the Tie 
Trunk ports and mark the disconnected wires for reconnecting the Tie 
Trunk ports to their normal configuration later. The D Impact Tool (AT-8762) 
is required to perform this step.
12. Use jumper wires (DT 24M-Y/BL/R/G and DT 24P-W/BRN) and the D 
Impact Tool to connect wiring between the two ports assigned in Step 9 at 
the cross-connect field. For example, if the two ports on the Analog Tie 
Trunk circuit pack are port 1 and 2, connect the wirings as shown below:
13. Check all wirings to verify good connections between the two test ports.
14. Place a call from one voice terminal to another voice terminal using the Tie 
Trunk ports assigned. Dial TAC and extension. For example, if TAC of Tie 
Trunk group is 110 and station number is 5012, then dial 110 5012. If the 
call cannot be made, either one of these ports could be defective. There 
are four ports on the TN760. Try different combinations to determine 
defective ports.
15. If there is a defective port on the circuit pack, try to switch to an unused 
port. If all ports are normally used, then replace the circuit pack.
16. Disconnect the jumpers between two ports. Then use administration 
terminal and trunk printouts to restore all trunk group changes to normal 
values.
Port 1
(t1 stan) 
(E & M)
Port 2
(t1 comp)
(E & M)
T1
connected to
T12
R1
R12
T11
T2
R11
R2
E1
M2
M1
E2