LED Interpretation 
7-2
Attendant Console LEDs 
7
button associated with the lighted alarm lamp. If the lamp is turned off, and the 
alarm has not been resolved by the time maintenance reschedules testing, the 
green status LED will resume its steady state. The following alarms are 
displayed:
Attendant Console LEDs
The console has two red LEDs, labeled “ALM” and “ACK.” The ALM LED lights 
steadily when there is a Major or Minor alarm at the switch cabinet. The ACK LED 
lights steadily if the alarm has been successfully reported to INADS. If the system 
is unable to report the alarm to INADS, the LED flashes; this signals the attendant 
to call INADS and report the alarm.
ac-alarm
Administered Connection Alarm: a locally administered 
connection (ADM-CONN) has a Major, Minor, or Warning 
alarm active.
pr-awu-alm
Auto Wakeup Journal Printer Alarm: the automatic wakeup 
journal printer has a Major, Minor, or Warning alarm active.
ds1-alarm
DS1 Facility Alarm: a DS1-BD has an off-board Major, Minor, 
or Warning alarm active.
trk-ac-alm
Facility Access Alarm: The facility access trunk test feature 
is activated.
major-alrm
Major Alarm: The system has logged a Major Alarm.
mj/mn-alrm
Major/Minor Alarm: The system has logged a Major or Minor 
Alarm.
pr-pms-alm
PMS Printer: The Property Management System printer has 
a Major, Minor, or Warning alarm active.
rs-alert
Reset-Alert: reset system 2 or 3 has been performed.
cdr1-alrm
Call Detail Recording Alarm: The Primary CDR Link has a 
Major, Minor, or Warning alarm active.
cdr2-alrm
Call Detail Recording Alarm: The Secondary Link has a 
Major, Minor, or Warning alarm active.
pr-sys-alm
System Printer Alarm: The System Printer (SYS-PRNT) has a 
Major, Minor, or Warning alarm active.
pms-alarm
The Property Management System has a Major, Minor or 
Warning alarm active.