Maintenance Object Repair Procedures
9-14
ADX8D-BD (AUDIX Circuit Pack)
9
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in
digital-port (DP) mode. For circuit-pack-level problems, see ‘‘XXX-BD (Common
Port Circuit Pack)’’. Port-level problems are covered by ADX8D-PT.
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in
digital-port (DP) mode. For circuit-pack-level problems, see ‘‘XXX-BD (Common
Port Circuit Pack)’’. Port-level problems are covered by ADX8D-PT.
DEFINITY AUDIX
consists of two circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The
AUDIX system has an extensive maintenance strategy that is described in
DEFINITY AUDIX System Maintenance, 585-300-110.
which tests circuit pack components related to the TDM bus interface. The
AUDIX system has an extensive maintenance strategy that is described in
DEFINITY AUDIX System Maintenance, 585-300-110.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADX8D-BD
MINOR or
WARNING
WARNING
test board UUCSS sh
AUDIX Circuit Pack