Panasonic AK-HRP900P ユーザーズマニュアル

ページ / 24
9
Pin No
8
9
10
11
12
13
14
15
Signal
Y signal output
Pb signal output
Pr signal output
Sync signal input
DC 12V
Frame GND
TXD (H)
Signal
Y signal GND
Pb signal GND
Pr signal output
Sync signal GND
DC GND
TXD (C)
RXD (H)
RXD (C)
Pin No
1
2
3
4
5
6
7
CAMERA  I / F
MONITOR  OUT
G/L  IN
TALLY  IN
BREAKER
DC  12V  IN
Y
P
b
P
r
P/T  CONT
M
N
O
P
Q
R
S
_
Rear panel
1
7
2
3
4
5
6
8
9
10
11
12
13
14
15
TXD:
Data from camera to remote controller.
RXD:
Data from remote controller to camera.
N
Swivel stand control signal input connector [P/T CONT (RJ-45)]
Connects the swivel stand control signal output of the pan-tilt control panel (AW-
RP301).
O
Monitor signal output connector [Y/G, Pb/B, Pr/R] (BNC
k
3)
Outputs the analog signal from the camera.
The output can be changed to R, G, B/Y, Pb, Pr by the camera menu setting.
P
Synch signal input connector [G/L IN] (BNC
k
1)
Inputs the sync signal to the camera.  Input 3-value SYNC as the synch signal.
Q
Tally signal input connector [TALLY IN] (2-pin connector block)
Connected to the tally connector from the system.  When the HOT connector is at GND
level, the tally LED is lighted.
Controls and their Functions
M
Camera connector [CAMERA I/F]
Connected to the camera (AK-HC900P) with the attached cable.