VIVOTEK IP32133 ユーザーズマニュアル

ページ / 71
 
 
 
 
 
 
 
 
 
- 7 - 
 
www.vivotek.com 
 T: 
886-2-22404099 
 F: 
886-2-22404097 
configuration. 
 
Network Camera will automatically detect and operate in the available network 
interface with the priority of Ethernet than WLAN. Operating in either network mode, 
the LED will flash every second as heartbeat to indicate alive. 
 
 
 
Network Camera provides a general I/O terminal block with one digital input and one 
relay switch for device control. Pin 1 and pin 2 can be connected to an external sensor 
and the state of voltage will be monitored from the initial state 'LOW'. The relay switch 
of pin 3 and pin 4 can be used to turn on or off the external device. 
 
 
 
 
 
                           
 
 
 
1      DI- 
 
 
INPUT (Initial state of DI is low) 
2   DI+ 
 
 
INPUT (Max. 50mA, 12VDC) 
3   SW_COMMON  
OUTPUT (open from SW_OPEN at initial state) 
  
 
 
 
(close with SW_OPEN when set DO to ON) 
4   SW_NOPEN     
OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC) 
  Consult with the dealer of the peripherals for correct installation.