Panasonic BT-LH1850 ユーザーズマニュアル

ページ / 60
38
Main menu 
(continued)
39
INPUT SELECT
The underlined values are factory preset setting values.
Sub menu
Settings
Description
VIDEO
AUTO
NTSC
PAL
Selects the VIDEO input format. 
*
1
<AUTO>   Automatically selects NTSC or PAL.
<NTSC>   NTSC
<PAL>     PAL
NTSC SETUP
00
75
Selects NTSC setup level.
<00> Select this when the signal is at a 0 IRE setup level.
<75> Select this function when using 7.5 % setup signals. 
        (The unit internally adjusts the 7.5 % setup level to suit the black level)
DVI-I
DIGITAL
ANALOG
Selects DVI-I input mode.
<DIGITAL>   Selects digital input.
<ANALOG>  Selects analog input. 
DIGITAL
AUTO
VIDEO
COMP.
Selects a DVI-I digital input mode.
<AUTO>   Selects the input mode automatically depending on the input format.
<VIDEO> Selects component input.
<COMP>  Selects PC input.
ANALOG
YP
B
P
R
RGB-COMP.
Selects YP
B
P
R
 (component) or RGB input mode when DVI-I is set to ANALOG.
<YP
B
P
R
>          Selects YP
B
P
R
 signals
<RGB-COMP>  Selects the PC RGB signal.
COMPONENT 
LEVEL
SMPTE
B75
B00
Selects the YP
B
P
R
 (component) signal input level of DVI-I analog inputs.
<SMPTE>    Signal level complies with SMPTE and PB and PR are 0.7 V [p-p] at 100 % 
chroma.
<B75>        Select this when connecting a Betacam or similar device with a setup function. 
(The unit internally adjusts the 7.5 % setup level to suit the black level)
<B00>        Select this when connecting a Betacam or similar device without a setup function.
RGB-COMP.
Performs analog PC settings. (This page)
*
1
 
“AUTO” is the factory default, but select an appropriate format when there is risk that the input signal may be contaminated by outside 
noise.
„
„
RGB-COMP.
Selecting “ANALOG.” under “DVI-I” in the “INPUT SELECT” menu and selecting “RGB-COMP.” under “ANALOG” opens the following 
menu.
The underlined values are factory preset setting values.
Sub menu
Settings
Description
H POSITION
0 to 60
(Factory default setting: 30)
Adjusts horizontal image display position in 2-clock units.
*
2
V POSITION
0 to 15
(Factory default setting: 8)
Adjusts vertical image display position.
*
2
PHASE
0 to 31
(Factory default setting: 16)
Adjusts the clock phase in 1/32 clock period increments.
*
2
CLOCK
700 to 1900
(Factory default setting
*
3
)
Adjusts the sampling clock in 2 clock units.
*
2
WXGA H SAMPLE
1280
1366
Select a WXGA format.
<1280> Select a 1280 x 768 format.
<1366> Select a 1366 x 768 format.
RESET
Returns H POSITION, V-POSITION, PHASE and CLOCK settings in the 
RGB-COMP. input compliant format to their factory defaults.
*
2
 
Each (compatible) input format can be adjusted but not when user data is loaded (→page27 “SETUP LOAD”) or saved (→page27 
“SETUP SAVE”)
*
3
 
“CLOCK” factory default
Format
CLOCK
Format
CLOCK
640×480 (60 Hz) 
800
1280×768 (60 Hz) 
1664
800×600 (60 Hz) 
1056
1366×768 (60 Hz) 
1792
1024×768 (60 Hz) 
1344