JVC DT-3D24G1 ユーザーズマニュアル

ページ / 36
26
External control
 About the external control
This monitor has three external control terminals.
 MAKE/TRIGGER terminal (RJ-45): The following external control 
systems are available.
1  MAKE (make contact) system:
Controls the monitor by short-circuiting the corresponding pin 
terminal to the GND pin terminal, or disconnecting (opening) it.
2  TRIGGER (trigger) system:
Controls the monitor by sending the pulse signal 
instantaneously to the corresponding pin terminal.
→ “Using the MAKE/TRIGGER system” on the right.
 RS-485 terminal (RJ-45): Controls the monitor with the RS-485 
system (→ “Using the serial communication” on page 28).
 RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-
232C system (→ “Using the serial communication” on page 28).
Set the following items of “REMOTE SETTING” in SET-UP MENU 
according to the external control terminal and control system (→ 
“SERIAL TYPE,” “PARALLEL TYPE” on page 24).
Control 
terminal
Control system
The settings of this unit
“SERIAL 
TYPE” 
setting
“PARALLEL 
TYPE” 
setting
MAKE/
TRIGGER 
terminal
MAKE
MAKE
TRIGGER
TRIGGER
RS-485 
terminal
Serial 
communication
RS-485
RS485 
*1
RS-232C 
terminal
RS-232C
RS232C 
*1
*1
  For a monitor connected to a personal computer etc, select 
the terminal the equipment is actually connected to. For other 
monitors, select “RS485.”
Control priority is as follows.
MAKE > TRIGGER = serial communication = buttons and menu on 
the monitor
 You can use external control even when “CONTROL LOCK” is set to 
“VOL.LOCK” or “ALL LOCK.” (→ page 25)
 When the monitor is off (on standby), external control is not 
available. But certain external controls (starting/terminating 
communication, turning on the monitor) are available through the 
serial communication. (→ page 29)
<MAKE/TRIGGER system>
You can control the monitor by a personal computer or dedicated 
controller
*2
.
 “Using the MAKE/TRIGGER system” on the right.
*2
  The controller is not commercially available. Consult your dealer if 
you need it.
<Serial communication>
 
PC, etc.
RS-485 
IN
RS-485 IN
or
RS-232C
RS-485 
OUT
RS-485 
IN
RS-485 
OUT
RS-485 
OUT
 For the details, see page 28.
 Using the MAKE/TRIGGER 
system
The MAKE/TRIGGER terminal is configured as follows.
You can assign a function to each pin terminal in “REMOTE SETTING.”
(→ “PIN1, PIN2, PIN3, PIN4, PIN5” in “PARALLEL TYPE” on page 24)
 You cannot change the functions assigned to the pin terminals 
from 6th to 8th.
 
This is a female 
terminal.
Pin No.
Pin name
1
PIN1
2
PIN2
3
PIN3
4
PIN4
5
PIN5
6
TALLY 
*1
7
ENABLE 
*2
8
GND
*1
  The 6th pin terminal controls turning on or off the tally lamp 
(available to control even when the 7th pin terminal is invalid).
*2
  The 7th pin terminal makes the external control valid/invalid. 
Make sure to control the terminal by the MAKE system.
To assign the functions to the pin terminals
For the operation procedure, see page 18.
1  Select “REMOTE SETTING” on the SET-UP MENU.
2  Set “PARALLEL TYPE” to “SET.”
3  Select a pin name (“PIN1” – “PIN5”) for which you want 
to assign a function, then select the function you want 
to assign.
For the selectable functions, see the table on page 29.
Operation of the external control
1  Set “PARALLEL TYPE” of “REMOTE SETTING” to “MAKE” 
or “TRIGGER” in the SET-UP MENU.
2  Short-circuit the 7th pin terminal (ENABLE) to the 
8th pin terminal (GND) so that the monitor can be 
controlled by the external control.
3  When the “MAKE” system is selected:
 
Operate each function by short-circuiting the 
corresponding pin terminal to the 8th pin terminal 
(GND) or opening it.
 
When the “TRIGGER” system is selected:
 
Operate each function by pulse control, that is short-
circuiting the corresponding pin terminal to the 8th pin 
terminal (GND) for about 1 second and opening it.
 When changing the input with MAKE system, only one pin terminal 
must be short-circuited. (Other pin terminals must be opened.)
 When selecting the “TRIGGER” system, you can operate only one 
function at a time. Operate the functions one by one.