Makita EM4351UH ユーザーズマニュアル

ページ / 22
[4] DISASSEMBLY/ASSEMBLY
[4]-2. Engine and Shaft
R
epair
P  3/ 22
(1) Press down the tab of Cleaner plate assembly gently and separate Cleaner cover assembly from Cleaner plate assembly 
      by loosening M5x20 Hex socket head bolt. (Fig. 1
(2) Loosen 5x16 Tapping screw and loosen Clamp that holds Bullet terminals near Cleaner plate assembly. (Fig. 2)
(3) Disconnect Bullet terminals of Earth wire and Primary wire of Ignition coil from the wires of Stop switch. (Fig. 2)  
(4) Remove Control cable from Swivel of Carburetor; loosen the three nuts on Control cable to release the tension 
      between Swivel and Cable bracket of Insulator, then remove the stopper on Inner cable end from Swivel. (Fig. 3)
(5) For EM4351UH: Remove M5x8 Hex socket head bolt and M6x30 Hex socket head bolt in the holes of Pipe housing.
      (Fig. 4
      For EM4350UH and EM4350LH: Remove M5x8 Hex socket head bolt and M6x30 Hex socket head bolt from 
the threaded holes of Clutch case. (Fig. 5)
(6) Grab Shaft pipe complete by hand, then pull it off from Clutch case. 
      If Shaft sticks in Clutch case, use water pump pliers or the like to pull it off.
Note:  Be sure to wrap Shaft with a rag or the like to protect it from water pump pliers. (Fig. 6)
Clamp
Cleaner plate assembly
Swivel of Carburetor
Inner cable
5x16
Tapping
screw
M5x8 
Hex socket
head bolt
M5x8 Hex socket
head bolt
M6x20
Hex socket
head bolt
M6x20 Hex 
socket head bolt
Holes of 
Pipe housing
Threaded holes 
of Clutch case
M5x20 Hex socket
head bolt
Control cable
Fig. 1
Fig. 5
Fig. 6
Fig. 3
Fig. 4
Fig. 2
Tab of
Cleaner plate assembly
Cleaner cover
assembly
Bullet terminals
Cable bracket of Insulator 
Stopper on Inner cable end
Nut on Control cable end
(3 pcs.)
Swivel of Carburetor
Shaft
Rag
Water pump
pliers
Shaft pipe complete