Lennox Hearth 506033-35 ユーザーズマニュアル

ページ / 8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
FREESTANDING BLOWER SNAp SWITCh RETROFIT KIT
COUNTRY COLLECTION™ WOODSTOVES
p/N 506033-35 
Rev. NC, /2009
HEARTH PRODUCTS
KITS AND ACCESSORIES
KIT CONTENTS
1 ea. Blower Wire Harness (item #1)
1 ea. Snap Switch and Control Panel Housings (item #2)
1 ea. 6” of 3/4” Heat Shrink Tube (item #3)
2 ea. Butt Connectors (item #4)
3 ea. Wire Ties (item #5)
1 ea. Instruction Sheet
TOOLS NEEDED
5/32 Allen Wrench Or T Handle Wrench
Cutting Pliers
Wire Crimpers
9/16” Socket Wrench
9/16” Open End Wrench
Crescent Wrench
3/8” End Wrench
Large Flat Head Screwdriver
FPO
INSTALLATION INSTRUCTIONS FOR INSTALLING A BLOWER SNAp SWITCh 
RETROFIT KIT FOR USE WITh COUNTRY COLLECTION™ MODELS S60, SA60, 
SS20, ST20, S260 AND ST30 FREESTANDING WOODSTOVES
       WARNINGS
The  blower  must  be  plugged  directly  into  a  properly 
grounded three-prong receptacle, 20 VAC, 60 hz, single 
phase. Do not cut or remove the grounding prong from 
this plug.  Do not route power cord under or in front of 
appliance.
Installation must be in accordance with National Elec-
trical Code, ANSI/NFpA 70 - latest edition.  In Canada, 
the current CSA C22- Canadian Electrical Code - latest 
edition.
DANGER: Disconnect power before servicing blower.
In the event that you remove the blower for any reason, 
make sure a cover plate (available from Lennox hearth 
products) is installed before using the heater. Excessive 
rear wall temperatures will result if the stove is burned 
without the cover plate. The cover plate is not necessary 
if a blower has never been installed because a knock-out 
will be in place to act as the cover.
FREESTANDING BLOWER SNAp SWITCh RETROFIT KIT
Cat. No.
Model
Description
h798
SSK-BLWR-FSB700 Blower Retrofit Kit, FS Woodstoves
Figure 1 - Kit Contents
GENERAL INFORMATION
This retrofit kit works in conjunction with the optional 700-CFM room air 
circulation blower kit. The kit provides a variable speed control (rheostat) 
and snap switch, which will allow for the option of automatic thermal 
activation  of  the  blower,  when  desired  and  blower  speed  control  (see 
Blower Operation on Page 8).
If you encounter any problems, need clarification of these instructions or 
are not qualified to properly install this kit, contact your local distributor 
or dealer.
Read this instruction sheet in its entirety before beginning the installa-
tion.
ALL  WARNINGS  AND  pRECAUTIONS  IN  ThE  INSTALLATION  AND 
OpERATION  MANUAL  pROVIDED  WITh  ThE  AppLIANCE  AppLY  TO 
ThESE INSTRUCTIONS.
ShUT DOWN ThE STOVE AND ALLOW IT TO COMpLETELY COOL BEFORE 
pROCEEDING.

4
2
3
5