11.1.6 Moisture 
Sensibility 
 
The level of moisture sensibility of 
Telit GE863-PRO
3
 modules
 is “3”, according with standard IPC/JEDEC 
J-STD-020, take care of all the relative requirements for using this kind of components. 
 
Moreover, the customer has to take care of the following conditions: 
 
a) The shelf life of GE863 inside of the dry bag shall be 12 month from the bag seal date, when stored 
in a non-condensing atmospheric environment of <40°C / 90% RH 
 
b) Environmental condition during the production: ≤ 30°C / 60% RH according to IPC/JEDEC J-STD-
033A paragraph 5 
 
c) The maximum time between the opening of the sealed bag and the reflow process shall be 168 
hours if the condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected 
 
d) A baking is required if conditions b) or c) are not respected 
 
e) A baking is required if the humidity indicator inside the bag indicates 10% RH or more