Uniden GH 200 ユーザーズマニュアル

ページ / 34
Hydraulic Motor Rebuild 
14
311797B
Hydraulic Motor Rebuild
(Figure 5)
Removal
1. Relieve pressure, page 7.
2. Place drip pan or rags under sprayer to catch hydraulic oil 
that leaks out during repair.
3. GH130 Models:
- Follow Steps 2-5 of pump removal instructions, page 17.
GH200, GH230, GH300 Models:
- Follow Steps 4-8 of pump removal instructions, page 18.
4. Remove hydraulic lines (271, 288) from fittings (266) at top 
left and right side of hydraulic motor.
5. Loosen jam nut (264).
6. Unscrew and remove hydraulic motor cap (265).
7. Slide piston rod/hydraulic motor cap assembly (A) from 
hydraulic motor cylinder (263).
8. Remove yoke (257).
a. Clamp hydraulic motor cap (265) in vise with hydraulic 
motor piston rod facing up.
b. Use shortened Allen wrench to remove two screws 
(260) from spring retainer (261). Remove yoke, spring 
retainer, piston and trip rod assembly from hydraulic 
motor cap.
9. Cover spring retainer (261) with a rag to contain detent 
spring (258) and balls (259) when they are removed from 
yoke. Remove detent balls and spring. Remove spring 
retainer.
10.Put yoke in vise and remove piston rod assembly from 
yoke.
Installation
1. Put hydraulic motor cap (265) in vise.
2. Install yoke (257), spring retainer (261), piston and trip rod 
assembly in hydraulic motor cap (265). Use shortened Allen 
wrench to install two screws (260) in spring retainer to 
secure piston rod assembly to hydraulic motor cap.
3. Slide piston rod assembly into hydraulic motor 
cylinder (263).
4. Screw down hydraulic motor cap (265). Unscrew hydraulic 
motor cap until inlet and outlet align with hydraulic line 
fittings and test hole in hydraulic motor cap points toward 
belt guard (117).
5. Torque jam nut (264) against hydraulic motor cap (265) to 
150 ft-lb (17 N·m).
6. Fig. 5. Install hydraulic lines (271, 288) to fittings (266) to 
top left and right side of hydraulic motor; torque to 40 ft-lb 
(54.2 N·m).
7. GH130 Models:
- Follow Step 2 of pump installation instructions, page 17.
GH200, GH230, GH300 Models:
- Follow Steps 2-7 of pump installation instructions, page 
19.
8. Start engine and operate pump for 30 seconds. Turn engine 
OFF. Check hydraulic oil level and fill with Graco hydraulic 
oil, page 6.
FLYING PARTS HAZARD
Detent spring has high energy potential. If detent 
spring is released without due care detent spring and 
balls could fly into the eyes of the disassembler. 
Wear safety glasses when removing or installing 
detent spring and balls. Failure to wear safety 
glasses when removing detent spring could result in 
eye injury or blindness.
FLYING PARTS HAZARD