Uniden GH 200 ユーザーズマニュアル

ページ / 34
Displacement Pump ProConnect 
18
311797B
Displacement Pump ProConnect 
GH200/230/300 Only
(Figures 13-27)
See pump manual 311845 for pump repair.
Removal
1. Flush pump.
2. Relieve pressure, page 7.
3. (Fig. 13) Remove suction hose (114).
F
IG
. 13
4. (Fig. 14) Remove paint hose fitting (190) and paint hose 
(63) from pump fitting.
F
IG
. 14
5. (Fig. 15) Slide coupler cover (193) up to fully expose rod 
couplers (179).
F
IG
. 15
6. (Fig. 16) Remove rod couplers (179).
F
IG
. 16
7. (Fig 17) Remove pin.
F
IG
. 17
ti8827a
ti8828a
190
63
ti8829a
193
179
ti8830a
179
179
ti8831a
247