Chauvet 648 ユーザーズマニュアル

ページ / 21
 
 
 
 
Impulse™ 648 User Manual Rev. 6 
Page 15 of 21 
General Troubleshooting 
 
Symptom 
Possible Cause 
Possible Action 
Circuit breaker or fuse 
keeps blowing 
· 
Excessive load on the circuit 
· 
Make sure that the total load does not 
exceed 80% of the breaker or fuse 
nominal current 
· 
Short circuit along the power lines 
· 
Check the power lines and power cords 
Product does not power 
up 
· 
No energy on power outlet 
· 
Check power outlet 
· 
Change to another outlet 
· 
Loose or damaged power cord 
· 
Check the power cord 
· 
Blown fuse 
· 
Replace blown fuse with a good one of 
the same type and rating 
· 
Internal problem 
· 
Send product for repair 
Product does not 
respond to DMX 
· 
Wrong starting address on the 
product 
· 
Set the correct starting address on the 
product 
· 
Use the right fader(s) on the controller 
· 
Wrong DMX personality on the 
product 
· 
Set the correct DMX product’s 
personality  
· 
Assign the faders accordingly 
· 
Wrong polarity setting on the DMX 
controller 
· 
Change the signal polarity on the 
controller 
· 
Loose or damaged DMX cable 
· 
Check the DMX cable before the faulty 
unit 
· 
Internal problem 
· 
Send product for repair 
Intermittent DMX 
Problems 
· 
Signal cables are not DMX 
compatible 
· 
Replace non DMX cables with true 
DMX cables 
· 
Interference with AC or radio 
signals 
· 
Keep DMX cables away from AC wires 
or radio equipment 
· 
DMX cable too long 
· 
Install an optically coupled DMX 
amplifier right before the product with 
intermittent problems 
· 
Too many products connected 
· 
Install an optically coupled DMX 
amplifier after unit #32 
· 
Terminator not connected 
· 
Install a terminator, as indicated in the 
DMX Primer section. 
 
 
 
If you still experience problems after trying the above solutions, contact 
CHAUVET® Technical Support.