Cooper Lighting GPF15SPW764 プリント
142
S T R E E T W O R K S O u t d o o r L i g h t i n g S o l u t i o n s
C o o p e r L i g h t i n g
NOTE: 1 Refer to technical section for lamp/ballast/voltage compatibility. 2 250/400W, 400/250W MH, HPS, and 400W MH only. 3 1000W only. 4 Available in MH only. 1000W requires reduced envelope lamp. 5 Available in HPS
only. 6 Not available in 1000W. 7 MOV option is not available for any system requiring a three position terminal block (Example—120/240V incoming line). In order for MOV option to function center terminal of three position
terminal block must be connected to “Earth” ground. 8 400W or below, except for 400W Mag. Reg.
terminal block must be connected to “Earth” ground. 8 400W or below, except for 400W Mag. Reg.
L AT C H E S
Formed aluminum flush
draw-action latches offer easy
access to lamp compartment
without tools.
H O U S I N G
Aerodynamically designed,
architecturally styled die-cast
aluminum housing. Standard dark
bronze polyester powder finish.
Other finish colors available.
Consult your Streetworks
Representative. ANSI
wattage/source label. Optional
NEMA twistlock photocontrol
receptacle.
D O O R
Spring-loaded die-cast aluminum
door with integral cast hinges for
removal without tools. Door gasket
is closed-cell silicone, providing
maximum protection of interior
components from the elements.
L E N S
Heat- and impact-resistant
tempered glass lens.
R E F L E C T O R
Computer designed precision
formed reflector system delivers
superior beam control and
efficiency.
B A L L A S T
Ballast components are hard
mounted to fixture housing for
maximum heat dissipation and
extended component and lamp life.
Plastic terminal block. Prewired
with 3' 14/3 STWA cord.
M O U N T I N G
Heavy-duty steel yoke provides flex-
ibility in mounting to a variety of
surfaces. Slipfitter for 2 3/8" to 3"
O.D. tenon and trunnion mount also
available.
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R
: G P F 1 5 S P W 7 6 4
S L I P F I T T E R , Y O K E , O R T R U N N I O N - M O U N T E D F L O O D L I G H T
OPTIONS (add as suffix)
1=Single Fuse, Internally Mounted (120 or 277V)
2=Double Fuse, Internally Mounted (208, 240, or 480V)
4=Photocontrol Receptacle
BK=Black
AP=Grey
A=Captive Door Screws
C=Slipfitter 2 3/8" to 3" O.D.—cord thru housing
H=Plug-in Starter Receptacle
1=Single Fuse, Internally Mounted (120 or 277V)
2=Double Fuse, Internally Mounted (208, 240, or 480V)
4=Photocontrol Receptacle
BK=Black
AP=Grey
A=Captive Door Screws
C=Slipfitter 2 3/8" to 3" O.D.—cord thru housing
H=Plug-in Starter Receptacle
6
M=MOV Lightning Surge Protectors
7
R=Removable Power Tray
8
S=Slipfitter 2 3/8" to 3" O.D. with leads thru fitter
T=Trunnion Mount
U=UL/CSA Listed
W=Wall Mount
T=Trunnion Mount
U=UL/CSA Listed
W=Wall Mount
ACCESSORIES (order separately)
OA1179=Top/Bottom Visor
OA1180=Side Visor
OA1181=Wire Guard
OA1182=Vandal Shield
OA1208=TufGuard Vandal Shield
VS/NK=Vandal Shield (For Wattages Below 1000W)
VS/NK/1000=Vandal Shield (For 1000W Units)
OA1179=Top/Bottom Visor
OA1180=Side Visor
OA1181=Wire Guard
OA1182=Vandal Shield
OA1208=TufGuard Vandal Shield
VS/NK=Vandal Shield (For Wattages Below 1000W)
VS/NK/1000=Vandal Shield (For 1000W Units)
GPF
GENERAL PURPOSE FLOOD
150-1000W MH/HPS/MERCURY
F L O O D L I G H T I N G
E P A :
Effective Projective Area:
2.7
S H I P P I N G D A T A
Approximate Net Weight:
59 lbs. (27 kgs.)
O P T I O N S + A C C E S S O R I E S
[ M u s t b e l i s t e d i n t h e o r d e r s h o w n a n d s e p a r a t e d b y a d a s h ]
STREETWORKS
™
OPTIONS +
ACCESSORIES
(See Below)
ACCESSORIES
(See Below)
PRODUCT
FAMILY
GPF=General
FAMILY
GPF=General
Purpose
Flood
Flood
LAMP WATTAGE
15=150W
20=200W
25=250W
40=400W
75=750W
91=1000W
24=250/400
15=150W
20=200W
25=250W
40=400W
75=750W
91=1000W
24=250/400
wired 250W
42=400/250
wired 400W
LAMP TYPE
1
S=High Pressure
Sodium
V=Mercury
M=Metal Halide
R=Super Metal Halide
M=Metal Halide
R=Super Metal Halide
BALLAST TYPE
1
H=Reac./HPF
N=Hi. Reac./NPF
P=Hi. Reac./HPF
R=Reac./NPF
W=CWA
C=CWI
M=Mag. Reg.
K=10KV CWA
N=Hi. Reac./NPF
P=Hi. Reac./HPF
R=Reac./NPF
W=CWA
C=CWI
M=Mag. Reg.
K=10KV CWA
VOLTAGE
1
2=120V
0=208V
4=240V
7=277V
8=480V
9=347V
W=Multi-Tap wired 120V
N=Multi-Tap wired 277V
5T=5-Tap wired 277V
0=208V
4=240V
7=277V
8=480V
9=347V
W=Multi-Tap wired 120V
N=Multi-Tap wired 277V
5T=5-Tap wired 277V
2
DISTRIBUTION
76=7x6
77=7x7
76=7x6
77=7x7
3
12=1x2
4
23=2x3
4
24=2x4
5
43=4x3
4
44=4x4
5
55=5x5
5
62=6x2
4
65=6x5
4
O P T I O N A L C O L O R S
[ S t a n d a r d c o l o r i s b r o n z e , o t h e r f i n i s h c o l o r s a v a i l a b l e . C o n s u l t y o u r C o o p e r L i g h t i n g r e p r e s e n t a t i v e ]
BK
Black
Black
AP
Grey
Grey
B
D
E
C
A
A
A
B
D
E
C
B
D
C
Fixture
A
B
C
D
E
Yoke
(in.)
20 1/2
18 1/2
22 1/2
4
S
(mm)
521
470
572
102
Trunnion
(in.)
20 1/2
18 1/2
24 3/8
2 9/16
3 5/16
(mm)
521
470
619
65
84
Slipfitter
(in.)
20 1/2
18 1/2
28 1/32
5 3/16
4 11/32
(mm)
521
470
712
132
110
Y O K E M O U N T
T R U N N I O N M O U N T
S L I P F I T T E R M O U N T
NOTE: Depth Dimension: 150-400W HPS and MH, 1000W HPS 9 1/2" [241]. 1000W MH 10 1/2" [267].