1.11  Hardware Management Subsystem 
The hardware management features enable the board to be compatible with the Wired 
for Management (WfM) specification.  The board has several hardware management 
features, including the following: 
•  Fan monitoring and control 
•  Thermal and voltage monitoring 
•  Chassis intrusion detection 
1.11.1 
Hardware Monitoring and Fan Control 
The features of the hardware monitoring and fan control include: 
•  Fan speed control controllers and sensors integrated into the Intel ICH10R 
•  Remote thermal diode sensor for ambient temperature sensing 
•  Thermal sensors in the processor, Intel 82P43 MCH, and Intel 82801JIR (Intel 
ICH10R) 
•  Power supply monitoring of five voltages (+5 V, +12 V, +3.3 V, +1.125 V, and 
+VCCP) to detect levels above or below acceptable values 
•  Thermally monitored closed-loop fan control, for all three fans, that can adjust the 
fan speed according to thermal conditions 
 
1.11.2 
Fan Monitoring 
Fan monitoring can be implemented using Intel
®
 Desktop Utilities or third-party 
software.   
 
 
For information about  
Refer to 
The functions of the fan headers 
Section 1.12.2.2, page 33 
 
 
1.11.3 
Chassis Intrusion Detection 
The board supports a chassis security feature that detects if the chassis cover is 
removed.  The security feature uses a mechanical switch on the chassis that attaches 
to the chassis intrusion header.  When the chassis cover is removed, the mechanical 
switch is in the closed position. 
 
 
For information about  
Refer to 
The location of the chassis intrusion header