Intel BLKDP43BF-10PACK ユーザーズマニュアル

ページ / 88
Intel Desktop Board DP43BF Technical Product Specification 
56 
 
Figure 16 shows the locations of the localized high temperature zones. 
 
Item Description 
Processor voltage regulator area 
B Processor 
Intel 82P43 MCH 
Intel 82801JIR (Intel ICH10R) 
Figure 16.  Localized High Temperature Zones 
Table 29 provides maximum case temperatures for the board components that are 
sensitive to thermal changes.  The operating temperature, current load, or operating 
frequency could affect case temperatures.  Maximum case temperatures are important 
when considering proper airflow to cool the board. 
Table 29.  Thermal Considerations for Components 
Component  
Maximum Case Temperature 
Processor 
For processor case temperature, see processor datasheets and 
processor specification updates 
Intel 82P43 MCH  
103 
o
C (under bias) 
Intel 82801JIR (Intel ICH10R) 
112 
o
C (under bias)