Hydraulic System
Page 4 - 30
Excessive Wheel Motor Case Drain Flow
Cause
Correction
Excessive internal wear in wheel motor.
Disassemble motor completely. Inspect parts and
replace as necessary. Case drain flow should not
exceed 2 gal/m (7.6 L/m) at full pressure.
Noisy Gear Pump Caused by Cavitation
Cause
Correction
Oil too heavy.
Change to proper viscosity oil.
Suction line restricted.
Check for bent or collapsed suction line. Check suction
screen in reservoir for blockage - drain and clean
reservoir if necessary.
Air leak in suction line.
Tighten fittings or repair suction plumbing.
Foaming Oil
Cause
Correction
Low oil level.
Fill reservoir.
Air leak in suction line.
Tighten fittings or repair suction plumbing.
Wrong kind of oil.
Drain and flush system. Fill with correct oil.
Front (Rear) Reels Will Not Turn
Cause
Correction
Solenoid Valve MSV1 (MSV2) not shifting.
Do electrical diagnostics to make sure that voltage is
being applied to MSV1 (MSV2) and that there is no
electrical fault. See Chapter 5 - Electrical System.
Test solenoid coil. Replace if faulty. See Chapter 5 -
Electrical System.
Do cartridge valve service procedure for valve MSV1
(MSV2).
Interchange MSV1 and MSV2 and check operation.
Replace faulty valve.