HP 590159-421 ユーザーズマニュアル

ページ / 58
HP Hard Drives
HP Hard Drives
HP Hard Drives
HP Hard Drives
NOTE:
NOTE:
NOTE:
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller,
and the server backplane) should operate at the same data transfer rate or the system
bandwidth will be negotiated down to an acceptable level for all components.
NOTE:
NOTE:
NOTE:
NOTE: Hard drives have either a one year or three year warranty; refer to the specific
hard drive QuickSpecs for details.
SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives
SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives
SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives
SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives
NOTE:
NOTE:
NOTE:
NOTE: A minimum of one SATA Non-Hot Plug hard drive is required ONLY when
purchasing Non-Hot Plug CTO Chassis Model (P/N 491531-B21) in Step 1.
 
HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard
Drive
507774-B21
HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard
Drive
507772-B21
HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty
Hard Drive
458941-B21
SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives
SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives
SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives
SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives
HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Entry 1yr Warranty Hard
Drive
458947-B21
HP Storage Controllers
HP Storage Controllers
HP Storage Controllers
HP Storage Controllers
NOTE:
NOTE:
NOTE:
NOTE: A minimum of one Smart Array Controller is ONLY required when purchasing
Hot Plug SFF CTO Chassis Model (P/N 593352-B21) in Step 1.
NOTE:
NOTE:
NOTE:
NOTE: The below storage controllers are intended for use with internal drives in the
Hot Plug CTO Chassis Model (P/N 491532-B21).
NOTE:
NOTE:
NOTE:
NOTE: With the HP Smart Array P410 Controller, the addition of the battery backed
cache upgrade enables BBWC, RAID 5, 5+0, array expansion, logical drive
extension, RAID migration, and stripe size migration. In order to upgrade to RAID 6, at
least 256MB Cache and a Battery is required in addition to the Smart Array Advanced
Pack license (P/N 516471-B21).
NOTE:
NOTE:
NOTE:
NOTE: To use the internal only PCI-e slot when purchasing the Hot Plug CTO
Chassis, a HP Smart Array P410 controller must be selected.
 
HP Smart Array P812/1G FBWC 2-ports Int/4-ports Ext PCIe x8 SAS Controller
487204-B21
HP Smart Array P410/1G FBWC 2-ports Int PCIe x8 SAS Controller
572532-B21
HP Smart Array P410/512 FBWC 2-ports Int PCIe x8 SAS Controller
578230-B21
HP Smart Array P410/ZM 2-ports Int PCIe x8 FIO SAS Controller
462860-B21
HP Smart Array P410/256 BBWC 2-ports Int PCIe x8 FIO SAS Controller
491195-B21
HP Hot Plug HDD
HP Hot Plug HDD
HP Hot Plug HDD
HP Hot Plug HDD
Backplane Option
Backplane Option
Backplane Option
Backplane Option
NOTE:
NOTE:
NOTE:
NOTE: A minimum of one Hot Plug HDD Backplane option is ONLY required when
purchasing Hot Plug CTO Chassis Model (P/N 491532-B21) in Step 1.
HP 2 HDD Backplane G6 FIO Kit
NOTE:
NOTE:
NOTE:
NOTE: Supports LFF hard drives only.
518593-B21
HP 4 Hard Drive Hot Plug Backplane G6 Kit
NOTE:
NOTE:
NOTE:
NOTE: Supports LFF hard drives only.
512181-B21
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
Configuration Information - Factory Integrated Models
DA - 13247   Worldwide — Version 51 — November 14, 2011