Zenoah EB7001 ユーザーズマニュアル

ページ / 14
GB-8
EB7001
6. Set up
FLEXIBLE HOSE and SWIVEL JOINT
1. Connect the blower and swivel joint with flexible hose.
Clamp both ends of the flexible hose securely with
the hardware supplied with the unit.
 NOTE
  A light lubricant may be used to ease assembly of
flexible pipe to blower elbow.
CONTROL HANDLE
• Set up the control handle to the swivel joint and tighten
the screw on the control handle holder.
BLOW PIPES
• Connect the swivel joint, straight pipe and pipe end.
Push the pipes together and turn them so they lock in
relation to one another until the connection is locked.
(1) Control handle
(2) Swivel joint
(3) Screw
(1)
(4)
(3)
(2)
(1) Flexible hose
(2) Swivel joint
(3) Clamp (Large)
(4) Clamp (Small)
(1)
(3)
(2)