Husqvarna WH5218 / 966638603 ユーザーズマニュアル

ページ / 52
ContRols
19
IMPORTANT INFORMATION
Experience indicates that alcohol blended 
fuels (called gasohol, ethanol or methanol) 
can attract moisture which leads to separation 
and formation of acids during storage. Acidic 
gas can damage the fuel system of an engine 
while in storage. To avoid engine problems, 
the fuel system should be emptied before 
storage of 30 days or longer. Drain the gas 
tank, start the engine and let it run until the 
fuel lines and carburetor are empty. Use fresh 
fuel the next season. See Storage Instructions 
for additional information. Never use engine 
or carburetor cleaners in the fuel tank or 
permanent damage may occur.
Fuel Shutoff Valve
The fuel shutoff valve is placed on the fuel line below 
the fuel tank. The valve is on when the turn lever is 
parallel to the fuel line. The OFF position will have the 
turn lever running perpendicular to the fuel line. See 
illustration.
Fuel Tank
The machine has one fuel tank. The tank volume is 6 
gallons / 22.7 liters.
The engine should run on a minimum of 87-octane 
unleaded gasoline (no oil mix). Also see Technical 
Data concerning methanol and ethanol fuels.
When operating in temperatures below 32° F. (0° C.), 
use fresh, clean winter grade gasoline to help insure 
good cold weather starting.
WARNING!
The engine and the exhaust system, 
become very hot during operation.
Risk for burns if touched.
Allow engine and exhaust system to 
cool at least two (2) minutes before 
refueling
WARNING!
Fill to bottom of filler neck. Do not 
overfill. Wipe off any spilled oil or fuel. 
Do not store, spill or use gasoline 
near an open flame.
8062-007
Fuel shutoff valve - closed (OFF)
8062-003
Fuel cap