American Standard 2908.XXXW ユーザーズマニュアル

ページ / 4
INSTALLATION INSTRUCTIONS
752535-100 Rev. F
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
REMINISCENCE
DROP-IN™ 
WHIRLPOOL
2908.XXXW SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
T H A N K     Y O U . . .
for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.
To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor 
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect 
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, 
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and 
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead 
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.  
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
•  Safe-T-Heater 9075.120*
* see your American Standard Distributor
List of Required Components (not included):
•  Drain 1583.470*          •  Bath Filler* 
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun
Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  15 or 20 amp
      GFI Outlet
•  Cement, Plaster,
      Grout
229 x 305mm
(9 X 12)
FLOOR
CUTOUT
1-1/2 N.P.T.M. THREADS
ROUGH
FLOOR
1-1/2 O.D.TAILPIECE
70mm
(2-3/4)
117mm
(4-5/8)
LEVELING STRINGER
(NOT FOR SUPPORT)
RIM AT
DRAIN END
C/L OF OVERFLOW
616mm
(24-1/4)
73mm
(2-7/8)
464mm
(18-1/4)
79mm
(3-1/8)
149mm REF.
(5-7/8)
64mm REF.
(2-1/2)
1676mm
(66)
PUMP
PROVIDE ACCESS
TO PUMP FOR SERVICE
ON ALL INSTALLATIONS
914mm
(36)
457mm
(18)
330mm
(13)
INTEGRAL
FITTING DECK
152mm
(6)
C/L OF
DRAIN
OUTLET
OUTLINE OF 
CUTOUT
ON/OFF
SWITCH
INTEGRAL
SUPPORT
FEET
SAFE-T-HEATER
REMOVABLE BLANK
  66 x 36 x 24-1/4 In. (1676 x 914 x 616mm)
95 Lbs. (43 Kg.)
659 Lbs. (299 Kg.)
68 Gal. (257 L.)
55 Gal. (208 L.)
40 x 18 In. (1016 x 457mm)
53 x 28 In. (1330 x 718mm)
15 In. (381mm)
40 Lbs./Sq. Ft. (191 Kgs/Sq. m.)
23.8
44.5
GENERAL SPECIFICATIONS FOR 2908 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.
SYSTEM I PUMP
SYSTEM II PUMP