View Door
Directions for Replacing AeroGarden Pump
Installing New Pump
Removing Old Pump
Congratulations...
You have replaced your 
AeroGarden Pump!
TM
300177AA
Filter
Connector
Screw
Pump
Tower
Upside Down Grow Surface:
Pump Cover Plate
Wire Slot
Filter
Metal
Contact
Unplug AeroGarden. 
Remove the Bowl from the 
Base. Do not empty the 
water. 
Remove the Grow Surface
from the Bowl and place on 
a counter covered by a 
towel (your roots will be 
dripping with water). 
Hint: Lift the View Door and slide 
one hand into the Bowl to lift. 
Don’t worry if you gently tear 
some roots.
Turn the Grow Surface
upside down on the towel, 
with the back of the Pump 
Tower
 facing you. (see top 
right photo)
Take out Pump Filter, rinse 
it (no soap) and set it aside.
Remove the Pump Connector  
Screw
 in the Pump Connector
using a Phillips-head 
screwdriver.
Pull up on Pump Connector 
to disconnect it from the 
bottom of the Grow Surface.
Remove the Pump by inserting 
the flat-head screwdriver into 
the space under the pump. 
Push down on the handle of the 
screwdriver to lift the Pump out 
of the Pump Tower.
1
2
3
5
6
Pull wire out of Wire Slot
Discard old Pump in trash.
Remove part A with needle-nose 
pliers and discard in trash.
7
10
8
11
12
Adjust Pump Dial to the 2 o’clock position 
(2 clicks).
Replace and screw in the Connector Screw 
so it is hand-tight (no power tools, please!)
Place Pump Filter back into slot.
Place Grow Surface upright on towel and 
gently replace plants back into their original 
positions on the Grow Surface.
Place Grow Surface back into bowl and 
replace bowl on the Base. Press down 
firmly on the Grow Surface.
13
Plug the Pump Connector into the Grow 
Surface
 so that the Metal Contacts face up 
and out and the Connector Wire is inside the 
Wire Slot.
15
16
17
18
19
Insert the new Pump into the Pump Tower
making sure that:
a. The rubber feet of the Pump are facing up.
b. The Pump Connector Wire goes behind   
    and underneath the Pump.
c. Pump Cover Plate is snapped back onto  
    top of Pump.
14
Directions continued on back
Part A
Pump
Connector
Screw
Pump
Connector
Pump
Pump
Connector
Wire
If you have any questions please feel free to contact Customer Service: 
1-800-GROW-NOW (1-800-476-9669) or email: info
@
aerogrow.com
Wire Slot
Tools Needed:
 Flat-head screwdriver
 Phillips-head screwdriver
 Needle-nose pliers
Gently remove each plant 
from its Grow Surface 
Opening
 and place the plants 
upright in the Bowl so that 
the roots are in the water. 
Hint: Note where the plants were 
positioned on the Grow Surface.
4
9
Remove Pump Cover Plate – 
insert flat-head screwdriver 
into each of the 3 rectangular 
slots and turn screwdriver 90
   
to help pry out the cover plate. 
It is okay to use force.
I N T E R N A T I O N A L ,   I N C .
©2006 AeroGrow International, Inc