Troubleshooting 
 
 
Problem 
 
Engine will not start 
SOLUTION:  A 
Low/Surging pressure or no water flow 
SOLUTION:  B,C,D,E,F,G 
No chemical injection 
SOLUTION:  H,I,J,K 
Cause Solution 
A- Engine starting instructions not followed 
See engine manual for starting instructions 
B- Insufficient water supply 
See water supply section of this manual 
C- Plugged pump inlet filter 
See maintenance section of this manual 
D- Wrong nozzle 
Make sure high pressure nozzle is being used  
E- Plugged nozzle 
Remove nozzle, check for blockage 
F- Worn nozzle 
Replace nozzle 
G- Leak in pressure hose 
Replace pressure hose 
H- Wrong nozzle 
Make sure chemical nozzle is being used 
I- Back pressure from extra long pressure hose 
Use standard length hose 
J- Leak in chemical siphon hose 
Replace hose – use hose clamps if necessary 
K- Chemical strainer not submerged 
Make sure strainer is completely submerged  
 
                          Specifications 
 
 
 
1577541 
 
 
1577542 
 
PSI (bar) 
2600 (179) 
 
PSI (bar) 
2700 (186) 
GPM (l/min) 
2.5  (9.4) 
 
GPM (l/min) 
2.5 (9.4) 
Max Water Temp 
140
°F (60°C) 
 Max 
Water 
Temp 
140
°F (60°C) 
Noise Level 
75 dB 
 
Noise Level 
82 dB 
Dimensions 
L x W x H 
30.5 x 24 x 24.3 
 
Dimensions 
L x W x H 
30.5 x 24 x 24.3 
Weight 77 
lbs 
 
Weight 83 
lbs 
 
 
The manufacturer reserves the right to make improvements in design 
and/or changes in specifications at any time without incurring any 
obligation to install them on units previously sold. 
 
Any Questions, Comments, Problems or Parts Orders 