North Star 157394 ユーザーズマニュアル

ページ / 18
- 12 -
TROUBLESHOOTING
SYMPTOMS 
CAUSES 
REMEDIES
The water pump will not start 
The motor thermic protection is open 
Check the mains voltage (+/- 5% 
 
 
tolerance).  Check the phases 
 
 
in the plug are connected well.
The water pump will not enter  
The no-return valve does not seal 
Replace the valve or the gasket 
in bypass 
 
and check the pressure valve 
 
 
body wear.
 
Leakage from the water system  
Eliminate the leaks
 
of the gun 
The water pump does not reach  
Nozzle worn 
Replace the nozzle
maximum pressure
 
Pressure ball or adjustment housing  
Replace the faulty part
 
worn or spring broken
 
Pressure valve gaskets worn 
Replace the valve gaskets 
 
Pistons seal gasket worn 
Replace the gaskets 
 
Nozzle holding head in position  
Turn the head on high pressure
 
low pressure
Strong vibrations on the water pump 
Water supply insufficient 
Check the water supply flow and 
 
 
the relative pressure (2÷10)
 
 
Check the water filter and clean 
 
 
it if necessary
 
 
Prime the pump without the lance
 
Alien matter under a check valve 
Check the valves, clean and reassemble
The burner will not start 
Diesel filter blocked 
Clean the filter 
 
Diesel nozzle blocked 
Clean the filter 
 
Worn or broken electrodes 
Replace the electrodes 
 
The pressure switch remains open 
Replace the pressure switch 
 
Safety thermostat is open 
Replace the safety thermostat
Anormal noise of Diesel pump 
Low diesel 
Fill diesel tank or work on cold water 
No detergent suction 
High viscosity of the employed  
Further dilute the detergent 
 
detergent
 
Detergent filter blocked 
Clean the filter