North Star M1573001K.1 ユーザーズマニュアル

ページ / 30
Troubleshooting 
  19 
 
 
Problem 
Solution
 
Motor will not start 
SOLUTION:  A,B 
Low/Surging pressure or no water flow 
SOLUTION:  C,D,E,F,G,H 
No chemical injection 
SOLUTION:  I,J,K,L 
Cause 
Solution 
A- Tripped GFCI cord 
Reset GFCI cord 
B- Tripped motor relay 
Reset motor 
C- Insufficient water supply 
See water supply section of this manual 
D- Plugged pump inlet filter 
See maintenance section of this manual 
E- Wrong nozzle 
Make sure high pressure nozzle is being used  
F- Plugged nozzle 
Remove nozzle, check for blockage 
G- Worn nozzle 
Replace nozzle 
H- Leak in pressure hose 
Replace pressure hose 
I- Wrong nozzle 
Make sure chemical nozzle is being used 
J- Back pressure from extra long discharge hose 
Try shorter hose 
K- Leak in chemical siphon hose 
Replace hose – use hose clamps if necessary 
L- Chemical strainer not submerged 
Make sure strainer is completely submerged  
 
 
 
 
The manufacturer reserves the right to make improvements in design and/or 
changes in specifications at any time without incurring any obligation to install 
them on units previously sold. 
 
 
 
 
 
 
 
Any Questions, Comments, Problems or Parts Orders 
Call NorthStar Product Support 1-800-270-0810