STORAGE & MAINTENANCE
WARNING
RISK OF UNIT BURSTING.
 
DO NOT STORE / OPERATE UNIT IN 
A FREEZING ENVIRONMENT!
WINTERIZING:
For storage and transportation purposes in subfreezing ambient temperatures, 
it will be necessary to winterize this unit.  This unit must be protected to the 
lowest incurred temperature for the following reasons:
1.  If any part of the pumping system becomes frozen; excessive pressure may 
build up in the unit which could cause the unit to burst resulting in possible 
serious injury to the operator or bystanders. 
2.  The pumping system in this unit may be permanently damaged if frozen. 
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below 
32°F, you can protect your unit by following the procedure outlined below.
1.  Gather the following items:
a.  Two 5 gallon containers.
b.  One gallon of antifreeze.  (Use an environmentally safe antifreeze.)
c.  Water supply.
d.  Three foot hose, 1/2-3/4 I.D. with a 3/4 inch male garden hose fitting.
2.  Procedure:
a.  To start winterizing, unit must be primed and run  according to the "Start-
up/Cold Water Procedures" listed on page 16.
b.  After priming and running, shut off the unit and water supply.
c.  Relieve system pressure by pointing the trigger gun in a safe direction 
and  squeezing  the  trigger  until    water  flow  ceases  to  exit  the  Dual 
Lance   Assembly.
d.  Lock the trigger gun in the OFF position and remove the Dual Lance 
assembly.
e.  Remove the water supply hose from the unit and attach the 3 foot hose 
securely to the inlet connection.
f.  Shut off the detergent injector. 
g.  Fill one 5 gallon container with water.
h.  Holding the 3 foot hose in an upright position, completely fill the hose 
with water.  Then plug the hose outlet with  your thumb or finger.  Place 
the plugged end into the 5 gallon container of water.
i.  Start the unit.  Trigger the gun several times until all the air is worked 
out of the system (unit is primed).  It may be necessary to adjust the 
engine RPM down to an idle to aid in priming.
NOTE:  Proper  winterizing  is  based  on  the  recommended  manufacturer's 
instructions listed on the "Protection Chart" shown on the back label 
of most antifreeze containers. 
j.  With  the  trigger  gun  held  open,  siphon  enough  water  out  of  the  5 
gallon   container until there is just enough water left to mix with the 
antifreeze.
k.  Point the trigger gun into the empty container.
l.  Trigger the gun until the antifreeze begins  to exit the trigger gun. Release 
the trigger for 3 seconds, then trigger the gun for 3 seconds.  Continue 
cycling the trigger gun several times until all the antifreeze mixture is 
siphoned from the container.
m.  Detach the 3 foot hose from the unit and drain any excess antifreeze 
back into the 5 gallon container.
n.  Disconnect the hose and trigger gun  from the unit and drain any excess 
antifreeze back into the 5 gallon container.
o.  Store the hose, trigger gun and dual lance assembly with the unit in a 
safe area.
p.  Store antifreeze solution for next use or dispose of according to state 
EPA laws.
3.  Optional Procedure:
a.  Shut the unit and water supply off.
b.  Relieve system pressure by pointing the trigger gun in a safe direction 
and squeezing the trigger until  water flow ceases to exit the nozzle.
c.  Disconnect and drain the hose, trigger gun and dual lance assembly.
 
d.  Remove the hose from the inlet side of the heat exchanger coil.
e.  Start the unit and allow it to run until all the water exits the unit.  Once 
the water has stopped flowing from the unit, turn off. 
NOTE:  When using this procedure, caution should be used as ice chips can  
form from drops of water which could cause the unit to burst if starting 
before completely thawed.
COIL DRAIN PLUG
32˚F
0˚C