Ariens 938032 ユーザーズマニュアル

ページ / 24
EN - 13
3. Check oil level on dipstick. Oil level must 
be maintained at safe operating level. 
See SPECIFICATIONS on page 20. Se
Engine Manual for detailed information.
4. Replace cap.
To add oil:
 1. Turn engine off and let cool for at least 
three minutes.
2. Remove cap from oil fill (Item 11) and 
add 5W-30 oil. Do not overfill.
3. Replace cap.
4. Clean up any spilled oil.
TRANSPORTING UNIT
1. Always shut off engine, remove key and 
close fuel shut-off valve when 
transporting on a truck or trailer.
2. Use extra care when loading or 
unloading onto truck or trailer. Do not lift 
using discharge chute handle (Item 6).
3. Secure unit chassis to transport vehicle. 
Never secure from rods or linkages that 
could be damaged.
4. Do not transport unit while engine is 
running.
OPERATION
Start Engine (Recoil Start)
1. Check oil level. See Engine Oil on 
2. Position discharge chute (Item 8) in 
safe direction.
3. Move engine switch (Item 16) to ON 
position.
4. Open fuel shut-off valve (Item 20).
5. If engine is cold, turn choke (Item 15) to 
CLOSED position. 
NOTICE: Do not apply choke to a warm 
engine.
6. Push primer bulb (Item 17) twice.
NOTICE: Do not push primer bulb to start a 
warm engine.
7. Slowly pull recoil starter handle (Item 5) 
until engine compression makes pulling 
difficult. Let starter rewind a little, and 
then pull smoothly and quickly to start 
engine.
8. Repeat step 7 as needed.
9. Gradually open choke after engine 
starts. 
IMPORTANT: If engine does not start after 
three attempts, see TROUBLESHOOTING 
on page 19.
10. Pull auger control bar (Item 2) back to 
handlebar to start auger; release bar to 
stop auger.
Start Engine (Electric Start)
Models 938032, 033, 034
1. Check oil level. See Engine Oil on 
2. Position discharge chute (Item 8) in a 
safe direction.
3. Connect a power cord to power cord 
recepticle (Item 19) and then plug cord 
into a wall outlet.
CAUTION: Use cord that is minimum of 
 
13 amp, 16 Gauge, 3 wire grounded plug, UL 
listed, CSA Certified. Cord must be labeled 
suitable for outdoor use. 
4. Move engine switch (Item 16) to ON 
position.
5. Open fuel shut-off valve (Item 20).
6. If engine is cold, turn choke (Item 15) to 
CLOSED position. 
NOTICE: Do not apply choke to a warm 
engine.
7. Push primer bulb (Item 17) twice and 
then press electric start button (Item 18)
NOTICE: Do not push primer bulb to start a 
warm engine.
8. When engine starts, disconnect power 
cord from wall outlet, then disconnect 
cord from power cord recepticle.
IMPORTANT:  If engine does not start after 
three attempts, see TROUBLESHOOTING 
on page 19
.
9. Pull auger control bar (Item 2) back to 
handlebar to start auger; release bar to 
stop auger.
Discharge Chute
(Item 8)
Models 938030, 031, 032, 034
IMPORTANT: Always throw snow in a safe 
direction, away from people and windows. 
To control the discharge of snow:
1. Turn discharge chute handle (Item 6) in 
the direction you want to throw snow.
2. Loosen wing knob (Item 9) and move 
discharge chute deflector handle 
(Item 7) up or down to control snow 
throw height. 
3. Tighten wing knob in desired position. 
If chute becomes frozen and does not turn 
correctly, take unit into warm area until 
controls are unfrozen.
CAUTION: Do not use chute handle to lift the 
unit.