Makita EK6100 ユーザーズマニュアル

ページ / 28
23
Instructions for periodic maintenance
To ensure long life, prevent damage and ensure the full functioning of the safety features the following maintenance must be per-
formed regularly. Guarantee claims can be recognized only if this work is performed regularly and properly. Failure to perform the 
prescribed maintenance work can lead to accidents!
Users of the Power Cut must not perform any maintenance work not described in this Instruction Manual. All such work must be 
carried out by a MAKITA service centre.
Service, spare parts and guarantee
Maintenance and repair
The maintenance and repair of modern cutoff saws and their safety-related components requires qualiÞ ed technical training and a 
workshop equipped with special tools and testing devices.
We therefore recommend that you consult a MAKITA service centre for all work not described in this instruction manual.
The MAKITA service centres have all the necessary equipment and skilled and experienced personnel, who can work out cost-effective 
solutions and advise you in all matters.
To Þ nd your local distributor, please visit www.makita-outdoor.com 
General 
Entire Power Cut 
Clean exterior, check for damage. In case of damage, 
 
 
 
 
have repaired by a qualiÞ ed service centre immediately
 
Cutting disc 
Inspect regularly for damage and wear. 
6
 
Clutch 
Have inspected at a service center.
 Protection 
hood 
Clean 
19 
Before each start 
Cutting disc 
Inspect for damage and make sure the cutting wheel is 
 
 
 
right for the job 
 
Protective hood 
Adjust position 
16
 
Combination switch, 
Functional check 
 
 
 
Safety locking button, 
Functional check 
 
 
 
Throttle lever 
Functional check 
16
 
Tank cap 
Check for tightness
Every day 
Idle speed 
Check (cutting disc must not turn on idle) 
17
Every week 
Starter housing 
Clean to ensure proper air cooling 
12
 
Starter cable 
Check for damage 
21
 
V-belt 
Inspect for damage and wear 
18
 
Spark plug 
Check and replace if necessary 
20
 Mufß er 
Check tightness of mounting 
12
 
Screws and nuts 
Check their condition and that they are Þ rmly secured.
Monthly Air 
Þ lter insert 
Check the air Þ lter insert, clean as needed, 
 
 
replace after 500 operating hours 
19
Every 3 months Suction 
head 
Replace 
20
 Fuel 
tank 
Clean
Annually 
Entire Power Cut 
Check at an authorized service centre
Storage 
Entire Power Cut 
Clean exterior, check for damage. In case of damage, 
 
 
 
 
have repaired by a qualiÞ ed service centre immediately
 
Cutting disc 
Remove and clean 
13
 
Fuel tank 
Empty and clean
 Carburetor 
Run 
empty
Page