Multiquip ga6HB ユーザーズマニュアル

ページ / 86
ga6HB/6HeB 60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14) — pAgE 17
ComPonenTs (GeneRaToR)
120/240V
30A
0N
OFF
IDLE
CONTROL
OPERATION
SWITCH
ON
OFF
120
V
GA-6HB
120
20A
120
30A
AC CIRCUIT BREAKER
GFCI PROTECTED
120
AC VOLTMETER
120V
FULL POWER
SWITCH
120V
120V/240V
MANUAL RESET
P
O
W
E
R
F
A
U
L
T
120 V
20A
120 V
20A
10
4
12
8
11
1
IN SIMULTANEOUS USE 30 AMP MAX
6
7
2
120/240V
30A
0N
OFF
IDLE
CONTROL
120
V
GA-6HEB
120
20A
120
30A
AC CIRCUIT BREAKER
GFCI PROTECTED
120
AC VOLTMETER
120V
FULL POWER
SWITCH
120V
120V/240V
MANUAL RESET
P
O
W
E
R
F
A
U
L
T
120 V
20A
120 V
20A
IN SIMULTANEOUS USE 30 AMP MAX
9
ELECTRIC START
14
START
SWITCH
OPERATION
SWITCH
13
9
3
5
Figure 3. Generator Components
1. 
120/240v Output Receptacle – NEMA L14-30R  twist-
lock receptacle will provide 240V, 60 Hz @ 20.8 amps, 
or 120V@ 41.6 amps (X2) 60 Hz. Depending on the 
position of the full power switch.
2. 
120v Output Receptacle – NEMA L5-30R  twist-lock 
receptacle will provide 120V, 30 amps, 60 Hz.
3. 
120v Output Receptacle – NEMA L5-20R  twist-lock 
receptacle will provide 120V, 20 amps, 60 Hz.
4. 
lifting Ball Eye – Attach a rope or chain to this lifting 
eye when lifting of the generator is required. Never 
stand underneath the generator while it is being lifted. 
Place lifting eye in down position when not in use.
5. 
gFCi  sensing  module  –  Interrupts power when a 
ground fault exist.
6. 
main Breaker – This 2-pole, 23 amp circuit breaker 
protects the generator from short circuiting or 
overloading. When starting the generator always have 
the circuit breaker placed in the "
OFF" position.
7. 
AC-voltmeter  –  This voltmeter indicates (with a 
mark) the rated 60 Hz (single-phase) output voltage. 
In addition the voltmeter can also be used as a 
diagnostic tool. If the voltmeter indicator (needle) is 
below the rated voltage, engine problems may exist 
(low/high RPM's). To prevent damage to the generator 
or power tools turn the generator 
OFF and consult your 
authorized Multiquip service dealer.
8. 
idle Control switch – The generator is provided with 
an automatic idle control device for noise suppression 
and reduced fuel consumption. 
The automatic idle control automatically engages under 
a no-load condition. With the automatic idle control 
switched “
ON”, the engine revolutions will automatically 
drop to about 2600 rpm (low-speed operation) within 
3 seconds after the load stops. When the operation is 
resumed, the engine speed is automatically increased 
to about 3600 rpm (high-speed operation) as soon as 
the load is connected.
9. 
Operation switch –  Place switch in the "ON" position 
(up) for normal operation. To turn-off the generator, 
place the operation switch in the "OFF" position (down).
10. 
gFCi  duplex  Receptacles  –  NEMA 5-20R, GFCI 
receptacle will provide 120V@ 20 amps. 
11. 
ground  –  This ground connection point should be 
connect to a good earth ground (ground rod).
12. 
Charcoal Canister – A container filled with activated 
charcoal that traps gasoline vapors emitted by the 
fuel
 system.
13. 
start switch – Press this pushbutton switch to start 
the generator (GA6HEB only).
14. 
Battery  –  This unit is equipped with a 12 VDC 
battery. Replace with only recommended type battery 
(GA6HEB only).