page 24 — ga9.7He 60 Hz geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (04/29/10) 
OperatiOn/sHutdOwn
16.  The L14-30R receptacle is a dual voltage receptacle 
(120-240 volts). Reference Figures 23 and 24 to verify 
voltages at this receptacle.
Figure 23. 120/240V Receptacle (120V)
Figure 24. 120/240V Receptacle (240V)
17.  Connecting of loads (power tools, lighting ect.) to the 
generator receptacles can now be done.
 NOTICE
When using a combination of dual receptacles, total 
load  should  not  exceed  the  rated  capacity  of  the 
generator.
stopping the engine (Normal shutdown)
1.  Place 
main  circuit  breaker  (Figure  25)  in  the  OFF 
position.
Figure 25. Main Circuit Breaker (OFF)
2.  Place 
GFCI and AUX. circuit breakers (Figure 26) in 
the 
OFF positing.
Figure 26. GFCI/AUX. Circuit Breakers (OFF)
3.  Place idle control switch (Figure 27) in the 
OFF position.
Figure 27. Idle Control switch (OFF)
4.  Let engine run at idle with no load for 2-3 minutes.
5.  To  shut-down  the  engine,  place  the  generator's 
operation switch (Figure 28) in the 
OFF position).
Figure 28. Operation Switch (OFF)
6.  Remove all loads from the generator.
emergency shutdown
1.  Place operation switch (Figure 28) in the 
OFF position.
OFF
OFF