Multiquip DCA125USI3CAN ユーザーズマニュアル

ページ / 92
page 30 — DCa125USI3CaN 60 hz geNerator • operatIoN aND partS maNUal — rev. #2 (09/24/13) 
INSPECtION/SEtUP
CIrCUIt BreaKerS
To protect the generator from an overload, a 3-pole, 350 
amp, main circuit breaker is provided to protect the 
U,v, 
and W Output Terminals from overload. In addition two 
single-pole, 20 amp 
GFCi circuit breakers are provided to 
protect the GFCI receptacles from overload. Three 50 amp 
load circuit breakers have also been provided to protect the 
auxiliary receptacles from overload. Make sure to switch 
all circuit breakers to the OFF position prior to starting 
the engine.
lUBrICatIoN oIl
Fill the engine crankcase with lubricating oil through the 
filler hole, but 
DO NOT overfill. Make sure the generator is 
level and verify that the oil level is maintained between the 
two notches (Figure 28) on the dipstick. See Table 11 for 
proper selection of engine oil.
Figure 28. Engine Oil Dipstick
When checking the engine oil, be sure to check if the oil is 
clean. If the oil is not clean, drain the oil by removing the 
oil drain plug, and refill with the specified amount of oil as 
outlined in the 
ISUzU engine owner’s manual. Oil should 
be warm before draining.
Other types of motor oils may be substituted if they meet 
the following requirements:
 
„
 API Service Classification CC/SC
 
„
API Service Classification CC/SD
 
„
API Service Classification CC/SE
 
„
API Service Classification CC/SF
table 11. recommended motor oil
FUel CheCK
Refilling the Fuel System 
This generator has an internal fuel tank (Figure 29) located 
inside the enclosure base and may also be equipped with 
an additional trailer mounted fuel tank (option). 
alWaYS 
fill the fuel tanks with clean fresh 
#2 diesel fuel. Do Not 
fill the fuel tanks beyond their capacities.
Pay attention to the fuel tank capacity when replenishing 
fuel. The fuel tank cap must be closed tightly after filling. 
Handle fuel in a safety container. If the container does not 
have a spout, use a funnel. Wipe up any spilled fuel 
immediately.
Figure 29. Internal Fuel Tank System
  DANGER
Fuel spillage on a 
hot engine can cause 
fire or explosion. If fuel spillage occurs, 
wipe up the spilled fuel completely to 
prevent fire hazards. 
Never smoke 
around or near the generator.
  CAUTION
oNlY  properly  trained  personnel who have read 
and understand this section should refill the fuel tank 
system.