PAGE 24 — DCA-180SSV—  OPERATION AND PARTS  MANUAL — REV. #1  (04/14/10)
Output Terminal Familiarization
The “
Output Terminal  Panel  ” (Figure 8) is provided with the
following:
Three (3) 120/240V output receptacles @ 50 amp
Three (3) Circuit Breakers @ 50 amps
Two (2) 100V GFCI receptacles @ 20 amp
Two (2) GFCI Circuit Breakers @ 20 amps
Five (5) Output Terminal Lugs ( U, V, W, O, Ground)
Output Terminal Panel
The 
Output Terminal Panel (Figure 8) shown below is located
on the right-hand side (left from control panel) of the generator.
Lift up on the cover to gain access to receptacles and terminal
lugs.
NOTE
Terminal legs “O” and “Ground
are considered 
bonded grounds.
Figure 8. Output Terminal Panel
DCA-180SSV— OUTPUT  TERMINAL PANEL FAMILIARIZATION