Provision for voltage configuration is via a jumper plug (J5). All electrical connections
are made by quick release connectors to aid in servicing. Refer to Figure 4-4 for the
layout and to Appendix B for the interconnect and other drawings.
The 751H Control PCB is microcontroller based and provides the following functions:
are made by quick release connectors to aid in servicing. Refer to Figure 4-4 for the
layout and to Appendix B for the interconnect and other drawings.
The 751H Control PCB is microcontroller based and provides the following functions:
Cycles the four-way valve of the Regenerative Dryer.
Cycles the water drain solenoid valve.
Cycles the relief valve in response to the pressure sensor.
Cycles the Regenerative Dryer four-way valve and momentarily opens the water
drain solenoid valve at compressor startup. This reduces the pressure at the
compressor outlet to facilitate compressor starting.
compressor outlet to facilitate compressor starting.
LED D13 flashes at 1 second intervals as an indication that the controller is
functioning, and a watchdog timer is enabled to prevent any power line disturbances
from halting the processor.
functioning, and a watchdog timer is enabled to prevent any power line disturbances
from halting the processor.
Figure 4-4: Control Board Layout