Freecom LTO-5 HH 34376 ユーザーズマニュアル
製品コード
34376
SCSI Array module: 80-pin
SCA (SCSI and power)
SCSI Rack-mount: 68-pin HD
LVDS
SCA (SCSI and power)
SCSI Rack-mount: 68-pin HD
LVDS
SCSI Rack-mount: 68-pin HD
LVDS
LVDS
SAS connector
SAS Internal: mini-SAS SFF-
8482
SAS External: mini-SAS
SFF-8088
8482
SAS External: mini-SAS
SFF-8088
SAS Internal: mini-SAS SFF-
8482
SAS External: mini-SAS
SFF-8088
8482
SAS External: mini-SAS
SFF-8088
SAS Internal: mini-SAS SFF-
8482
SAS External: mini-SAS
SFF-8088
8482
SAS External: mini-SAS
SFF-8088
SAS Internal: mini-SAS SFF-
8087
SAS External: mini-SAS
SFF-8088
8087
SAS External: mini-SAS
SFF-8088
LTO-2 HH Ultrium 448
LTO-3 HH Ultrium 920
LTO-4 HH Ultrium 1760
LTO-5 HH Ultrium 3000
Power requirements,
Internal (including rack-
mount model)
Internal (including rack-
mount model)
+5V@2.5A (typical)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (typical)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (typical)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
5V@3.5A (typical)
+5V@3.7A (max)
+12V@0.7A (typical)
+12V@1.9A (max)
+5V@3.7A (max)
+12V@0.7A (typical)
+12V@1.9A (max)
Power requirements,
External
External
100 to 240 VAC,
50-60 Hz, auto-ranging, 0.7A
max
50-60 Hz, auto-ranging, 0.7A
max
100 to 240 VAC,
50-60 Hz, auto-ranging, 0.7A
max
50-60 Hz, auto-ranging, 0.7A
max
100 to 240 VAC,
50-60 Hz, auto-ranging, 0.7A
max
50-60 Hz, auto-ranging, 0.7A
max
100 to 240 VAC,
50-60 Hz, auto-ranging, 0.7A
max
50-60 Hz, auto-ranging, 0.7A
max
Power requirements,
Array Module
Array Module
+5V@2.5A (typical)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (typical)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
+5V@2.5A (max)
+12V@0.7A (typical)
+12V@2.1A (max)
N/A
N/A
Power Specifications
Power consumption
13 Watts idle
20 Watts typical
33 Watts max
20 Watts typical
33 Watts max
13 Watts idle
20 Watts typical
33 Watts max
20 Watts typical
33 Watts max
13 Watts idle
20 Watts typical
33 Watts max
20 Watts typical
33 Watts max
7 Watts idle
24 Watts typical
34 Watts max
24 Watts typical
34 Watts max
Operating:
50° F to 95° F (10° C to 35° C) if 6 CFM airflow is provided
50° F to 104° F (10° C to 40° C) if 8CFM airflow is provided for Full-Height, 5CFM airflow for Half-Height
50° F to 95° F (10° C to 35° C) if 6 CFM airflow is provided
50° F to 104° F (10° C to 40° C) if 8CFM airflow is provided for Full-Height, 5CFM airflow for Half-Height
Temperature range
Non-Operating: -40° F to 151° F (-40° C to 66° C)
Operating: 20 to 80% RH (Non-condensing, max wet bulb temperature = 26C)
Environmental
Specifications
Specifications
Non-condensing
humidity range
humidity range
Non-Operating: 10 to 95% RH (Non-condensing, max wet bulb temperature = 26C)
Standards Compliance
CSA Certification to C22.2, No.60950 (cCSAus)
TÜV EN60950 (IEC 60950 and EN60950)
CE Declaration of Conformity
FCC 47 CFR Parts 15
NOM
VCCI
C-TICK
RRL
BSMI
GOSH
CB Certificate and Report (IEC 60950)
TÜV EN60950 (IEC 60950 and EN60950)
CE Declaration of Conformity
FCC 47 CFR Parts 15
NOM
VCCI
C-TICK
RRL
BSMI
GOSH
CB Certificate and Report (IEC 60950)