Roland S-1608 ユーザーズマニュアル
7—Advanced Use
S-1608/S-0816 Digital Snake Owner’s Manual
59
Notes on Split Setups
•
A Split REAC device can only receive audio from the Master REAC device—it can’t receive audio
from a Slave REAC device (or another Split device).
from a Slave REAC device (or another Split device).
•
When a unit is set as a Split REAC device, its audio inputs are disabled.
•
An S-4000R can be connected to the REMOTE connector on a Split REAC device. However, it can
only be used for system and signal level monitoring—adjustment of Master/Slave device’s inputs
is not possible. (If you need to adjust the signal level coming from a Split device’s outputs, use
the input trim controls on the receiving device.)
only be used for system and signal level monitoring—adjustment of Master/Slave device’s inputs
is not possible. (If you need to adjust the signal level coming from a Split device’s outputs, use
the input trim controls on the receiving device.)
Setting the [REAC MODE] Switches
With their power off, set the units as follows:
1.
On the S-1608, set the [REAC MODE] switch to M.
2.
On the primary S-0816 (usually at the FOH position), set the [REAC MODE] switch to S.
3.
On each S-0816 used to receive audio splits from the stage, set the [REAC MODE] switch to SP.
If the [REAC MODE] switch setting is changed when the unit is powered on, the new setting won’t
take effect until the unit is powered off and then back on again.
take effect until the unit is powered off and then back on again.
S-1608_e.book 59 ページ 2007年4月23日 月曜日 午後12時57分