S-1608/S-0816 Digital Snake Owner’s Manual
 
S-4000R Unit: System Status Indicators
 
Indicator
Status
Definition
Troubleshooting Action
POWER
Lit
Power is received
• None (normal operation)
Dark
No power is received
• Make sure all REAC devices are turned on
• Check the RS-232C cable for damage
• Are you using an RS-232C cable with the proper wiring? 
(See Appendix B)
REAC
Lit
Communication is established
• None (normal operation)
Flashing
System power-up
• None (normal operation)
No REAC communication
• Make sure all REAC devices are turned on
• Check Cat5e cable connections
• Check the Cat5e cable(s) for damage
• Is the proper cable type being used? (See Page 40)
• If a switching hub is used, is it working?
• If a switching hub is used, is it properly connected? (See 
• If a switching hub is used, does it have the proper 
specification? (See Appendix C)
CTRL
Lit
REMOTE communication 
established
• None (normal operation)
Flashing
System power-up
• None (normal operation)
No REMOTE
communication
• Check the RS-232C cable for damage
• Are you using an RS-232C cable with the proper wiring? 
(See Appendix B)
 
S-4000R Unit: Error Indicators
 
Indicator
Status
Definition
Troubleshooting Action
CLIP 1/
SIG 1
Lit
The REAC connection has failed
• Check REAC cabling
• Check REAC connections
• Check in-line REAC Splitter S-4000-SP or switching hub (if 
used) on REAC connection
Flashing
Recovery from the above error
• None
CLIP 2
Lit
An exhaust fan on the Master 
REAC unit has stopped working
• Check the exhaust fan is working
• Turn off the power to prevent overheating and damage
• Consult with the nearest Roland Service Center
Flashing
Recovery from the above error
• None
CLIP 4/
SIG 4
Lit
REAC packets error detected on 
the unit connected to the 
S-4000R
• Check REAC cabling
• Check REAC connections
• Check in-line switching hub (if used) on REAC connections
SIG 2
Lit
An exhaust fan on a Slave/ Split 
REAC unit has stopped working
• Check the exhaust fan is working
• Turn off the power to prevent overheating and damage
• Consult with the nearest Roland Service Center
Flashing
Recovery from the above error
• None
CHANNEL
Display
Flashes 
“Er”
This happens whenever one of 
the previously described 
S-4000R error indicators lights 
or flashes
• Look for the source of the error
• Press [CLIP CLEAR / ENTER] to return to normal 
S-4000R operation