7-1   
   7 COMMUNICATION MODES
7
COMMUNICATION MODES
The communication modes are used for setting the Baud rate (Protocol), receiving a file (Data file in) 
and sending a file (Data file out). A data transfer program on your PC that supports (YMODEM) will be 
necessary to send or receive data files.
7.1
Setting of PROTOCOL
To transfer data files to and from the GTS-820A Series and PC, the Baud rates must be the same. The 
Baud rate selections are 600, 1200, 2400, 4800, 9600, and 19200.
Operating procedure
Operation
Display
1
Press the [F1](Protocol) key for protocol.
[F1]
2
To select the Baud rate, use the arrow key`s 
[F3-F6] to highlight your choice. When the 
correct Baud rate is highlighted, press the 
[ENT] key.
[F3] to[F6]
[ENT]
Prog Std
Mem Comm Adj Para
2003-10-10  15:30:40
COMMUNICATION MODES
[Press [F4] key.]
Communication                  
F1 Protocol
F2 Data file in
F3 Data file out
To set the protocol for measured data transferring, refer to  Chapter 8 “PARAMETERS SETTING 
MODE” .
.
Communication                  
F1 Protocol
F2 Data file in
F3 Data file out
Communication                  
 Speed         600  1200  2400
              4800  9600 19200
                               
             
←      →   ↑     ↓
Communication                  
F1 Protocol
F2 Data file in
F3 Data file out